Laserfiche WebLink
Environmental Health Department <br />Time In. 10.00 am <br />Time Out: 11:00 am <br /> <br />Swimming Pool Official Inspection Report <br />Name of Facility: ST FRANCIS YACHT CLUB Date: 07/23/2020 <br />Address: 14344 W TINSLEY ISLAND RIVER RTE, STOCKTON 95209 <br />Owner/Operator: ST FRANCIS YACHT CLUB Telephone: (415) 563-6363 <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: The underwater pool light was not functioning on the 3 foot end of the pool. Repair/replace within two <br />weeks. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />#9 Ladders and Handrails <br />OBSERVATIONS: A handrail is loose on the 8 foot section of the pool. Secure handrail within one week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 31118) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />#36 Pressure and Vacuum Gauges <br />OBSERVATIONS: The effluent pressure gauge is rusty and non-operable. Replace gauge within two weeks. <br />CALCODE DESCRIPTION: Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 275 gpm Chlorine: 4.8 ppm <br /> <br />Cyanuric acid: 50 ppm pH: 7.6 Combined chlorine: 0 ppm <br />NOTES <br />Routine inspection conducted this date. The followings were noted: <br />Influent: 18, 17, 17 psi; Effluent: 0 psi. <br />Inspection report was discussed with Ross Schiveley. The signature was not captured. <br />Inspection report will be e-mailed to the facility. <br />FA0003025 PR0360136 SC001 07/23/2020 <br />END 36-01 Rev. 06/30/15 <br /> Page 1 of 2 Swimming Pool OIR <br />Temp: ° F <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjcehd.com