Laserfiche WebLink
SAN JOAQUIN <br />—COUNTY— <br />Greatness row herr. <br />Environmental Health Department <br />Time In 1200. pm <br />Time Out: 1:23 pm <br /> <br />Swimming Pool Official Inspection Report <br />Name of Facility: VVESTPOINTE APARTMENTS NE SPA Date: 08/07/2018 <br />Address: 6465 N WEST LN, STOCKTON 95210 <br />Owner/Operator: PATMON COMPANY INC Telephone: (209) 951-4391 <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#4 Safety Equipment <br />OBSERVATIONS: Life ring is missing rope. Provide immediately. Corrected on site. <br />Hook is broken. Provide new hook in 2 days. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />#9 Ladders and Handrails <br />OBSERVATIONS: Double handrail is loose. Repair in 2 days. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111B) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />#22 Skimmer Assembly <br />OBSERVATIONS: One skimmer weir gate is missing. Provide weir gate in 2 days. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 105 gpm Chlorine: 7.4 ppm Temp: ° F <br /> <br />Cyanuric acid: 30 ppm pH: 7.4 Combined chlorine: 0.2 <br />NOTES <br />North West pool <br />Influent 14 PSI Effluent 5 PSI. <br />GFCI and lights are functioning. <br />OIR emailed to fcamacho1986@aol.com westpointeapts.cd@fpimgt.com <br />FA0002425 PR0360595 SC001 08/07/2018 <br />EHD 36-01 Rev. 06/30/15 Page 1 of 2 <br /> Swimming Pool OIR <br />ppm <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I vvww.sjcehd.com