Laserfiche WebLink
ProSeries XTPTM Specifications <br /> Thermostatic Water Heater for Commercial and Industrial Applications Tankless Electric Water Heater <br /> Applications Electrical configuration and <br /> • Booster(up to 180°F) requirements <br /> • Recirculation loop' All Eemax three phase units are custom made <br /> • Washdown processes to order and as such,are non-retumable and <br /> • Commercial kitchens/utility sinks Eanax non-refundable.Check your electrical supply, <br /> • Kitchen,wet bar,utility sinks making sure all criteria for operating your <br /> • Mop sinks Eemax water heater are met. <br /> • Dishwasher Eemax 480V and 208V <br /> • Handwashing(variable and fixed-flow) Three Phase Units Delta Configuration <br /> Requires:3 Lives and 1 Ground(earth) <br /> Performance Features Ll <br /> • Adaptive Stability TechnologyTm assesses the heater condition and ProSeries XTP is compatible with both delta and woe(Y)electrical <br /> configuration requirements When converting a Y configured unit to a <br /> shifts unit operation to ensure a consistent and reliable output ProSeries XTP delta configured model,the neutral leg is not required, L2 <br /> • Includes wall mounting bracket allowing for easy,flexible installation, �s <br /> reducing time and labor �PssryF N.mni.a <br /> • SafeStartTm engages upon start-up to avoid dry-fire occurrence C �L us ° v <br /> • 4-line,20-character LED display delivers an enhanced user LISTED C U� US r�us. <br /> experience-display relays system status&operation feedback <br /> • Built to last-constructed of powder-coated galvanized steel, <br /> stainless steel heating chambers and sheathed copper heating Special Design Service <br /> elements,protecting the heater and minimizing the occurrence of a Inquiries for units for unique applications are welcome. <br /> rust and corrosion Call our Technical Service department at 1-800-543-6163. <br /> • Self-diagnostics with intelligent controls actively protect heater in . Custom orders non-refundable <br /> installed environment <br /> • Flow activation at 0.5 GPM/1.89 LPM across product line Suggested Specification <br /> • Max flow of 20 GPM Tankless water heater shall be an Eemax model number <br /> • Fittings suit common plumbing connections(3/4'NPT) <br /> • Temperature stability at+/-1°F or+/-0.6°C output <br /> • High temperature limit switch enables safe operation Factory installation in a (N4/N4X/N4X6)enclosure. <br /> • Powered by three phase delta,capable of supporting locations Enclosure to be fitted with the following features: <br /> serviced by three phase wye or three phase delta power FP Freeze protection(-30oF) <br /> • Only one input water line,cold or hot,needed for installation EDS Non-fused disconnect <br /> • Factory set to 120°F <br /> • Compact size for flexible installation FDS Fused disconnect <br /> • User adjustable turn on flow EP Explosion proof(Cl D2 compliant) <br /> • User adjustable temperature settings 60°-180°F GFCI True RMS GFCI with digital display and reset <br /> • Inlet/outlet thermistors for precise temperature control SK 24"legs for free standing applications <br /> • Tamper resistant controls(hardware lockout) SB Siren and Beacon <br /> • IP25-rated cover prevents water intrusion within the system(water DC Dry contact <br /> run-off and minimal corrosion) ES Emergency stop-push button <br /> Optional Features(NEMA cabinet required) Tankless water heater must have water connections on the bottom <br /> • N4(powder coated steel),N4X(304SS)N4X6(316SS)enclosures and be constructed with NSF61 listed materials.Unit to accomodate <br /> • Free standing legs vertical(upright)or horizontal mounting orientations. Heating element <br /> • Freeze protection for harsh climate,up to-30°F to be sheathed,copper cartridge style,designed for field replacement. <br /> • Non-fused or fused electrical disconnect Tankless water heater to use 4 line,20 character LED digital display. <br /> • GFCI Display to include selectable Celsius/Fahrenheit,inlet temperature, <br /> • Explosion proof—C1 D2 Compliant,local certification required.Class outlet temperature,and set point temperature.Display to be capable of <br /> Z purge and pressurization system provided with pressure switch relaying flow rate in gallons per minute or liters per minute.Diagnostic <br /> for alarm controls.For classification other than C1 D2 please contact features to include error and fault code notifications via digital display. <br /> the factory to discuss options. Control board to maintain error/fault history.Water heater must be <br /> • Siren and beacon-audible and visual alarm(Cl D2 compliant when protected by redundant safeties and redundant safeties to include <br /> paired with explosion proof package) employ integrated flow meter that will ensure accurate turn-on/ <br /> • Display is visible regardless of NEMA cabinet selection turn-off flow rate.Unit shall have a 0.5 GPM turn on flow Water heater <br /> shall modulate power to the heating elements to maintain a user- <br /> Product Specifications selected output temperature between 60-180°F(subject to incoming <br /> Min.Operating Pressure: 35 PSI water temperature).The unit shall be equipped with both computer- <br /> Max.Operating Pressure: 150 PSI controlled and electromechanical auto resetting thermostat switches <br /> for high-limited temperature protection.Maximum operating pressure <br /> Optimum Operating Pressure: 60-90 PSI of 150 PSI.The water heater shall be fitted with 3/4'NPT fittings. <br /> 'In accordance with NEC guidelines,the water heater is designed for a ma>amum continuous duty cycle Heater shall employ technology that engages upon start-up to avoid <br /> of 3 hrs.at 100%power output.After 3 hrs.heater should be powered down for long enough to return dry-fire occurrence.Unit shall be Eemax or approved equal. <br /> heater and electrical infrastructure to ambient temperature. <br /> Information and product swarcahms antained m this document ue sub ed to change Avul notica REV 2020-01 17 <br />