Laserfiche WebLink
Environmental Health Department <br />Telephone: (209) 373-2700 Owner/Operator: LATHROP HOTEL LP <br />Inspection Type: Routine <br />Address: 15688 S HARLAN RD, LATHROP 95330 <br />Date: 07/01/2024Name of Facility:HOLIDAY INN <br />Reinspection on or after: <br />Swimming Pool Official Inspection Report <br />Program Element: 3612 - PUBLIC POOL/SPA - ADDITIONAL <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public <br />health and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />VIOLATIONS AND CORRECTIVE ACTIONS <br /> #10 Disinfectant Residual <br />OBSERVATIONS: The chlorine level of the spa is 0.0ppm. Immediately increase the spa chlorine level to the range of 3.0ppm <br />to 10.0ppm or face closure. <br />Chlorine was added. Re-checked at 3.0ppm <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall <br />maintain the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with <br />cyanuric acid or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to <br />10.0 ppm free chlorine or 4.0 ppm bromine. (CCR 65529) <br />This is (Major) Violation. <br />MAJOR <br /> #12 pH Level <br />OBSERVATIONS: The spa pH is greater than 8.0. Immediately take action to reduce the pH of the spa to the range of 7.2-7.8 <br />or face closure. <br />Acid was added. Re-checked pH at 7.8 <br />CALCODE DESCRIPTION: Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br />This is (Major) Violation. <br />MAJOR <br /> #35 Flow Meters <br />OBSERVATIONS: The spa is missing a flowmeter. Properly install a flowmeter by 2 weeks. <br />CALCODE DESCRIPTION: Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br />manufacturer's specifications. (CBC 3125B) <br />This is (Minor - Food) Violation. <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br /> PR0527636 07/01/2024 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD