My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
RIVER
>
26292
>
2800 - Aboveground Petroleum Storage Program
>
PR0516200
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 2:21:19 PM
Creation date
10/2/2024 7:52:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0516200
PE
2833 - AST FAC 100 K + 1 - </=1 M GAL CUMULATIVE
FACILITY_ID
FA0009335
FACILITY_NAME
MUNN & PERKINS
STREET_NUMBER
26292
Direction
E
STREET_NAME
RIVER
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
247-22-032
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
26292 E RIVER RD ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PO BOX 1928 <br />BENICIA, CA 94510 <br />TEL 707 346 5058 <br />FAX 707 922 2284 GEORGE REED INC. STI SP001 EXTERNAL INSPECTION <br />ESCALON, CA <br /> www.powerseicom 7,000 GALLONS OIL TANK <br /> <br />STI-SP001 External George Reed Inc. Escalon, CA Tank 7,000 Gal October 2024 Project #24-378 Rev0 <br />© 2024 PEI Inc. Page 12 of 43 Date Printed: 11/7/24 7:42 AM <br /> <br />7.2 Evidence of coating, cracking, crazing, peeling, and <br />blistering? Yes Minor coating failure on tank <br />Shell <br />7.3 Holes in roof? No <br />8.0 Venting Status Comment <br />8.1 Vents free of obstructions? Yes 2-in vent <br />8.2 Emergency vent operable? Lift as required? No No emergency vent <br />9.0 Insulated Tanks Status Comment <br />9.1 Insulation missing? N/A <br />9.2 Are there noticeable areas of moisture on the <br />insulations? N/A <br />9.3 Mold on insulation? N/A <br />9.4 Insulation exhibiting damage? N/A <br />9.5 Is the insulation sufficiently protected from water <br />intrusion? N/A <br />10.0 Level and Overfill Prevention Instrumentation <br />of Shop-Fabricated Tanks Status Comment <br />10.1 Has the tank liquid level sensing device been <br />tested to ensure proper operation? N/A <br />10.2 Does the tank liquid level sensing device operate <br />as required? N/A <br />10.3 Are overfill prevention devices in proper working <br />condition? N/A <br />10.4 <br />Is the leak detection unit in good condition? <br />Remove the device and check for proper <br />operations. <br />N/A <br />12.0 Electrical Equipment Status Comment <br />12.1 Are tank grounding lines in good condition? N/A No grounding wire present <br />12.2 Is electrical wiring for control boxes/lights in good <br />condition? Yes <br /> <br />Additional Comments: <br />___________________________________________________________ <br />___________________________________________________________ <br />___________________________________________________________ <br />___________________________________________________________ <br />___________________________________________________________ <br />___________________________________________________________ <br />___________________________________________________________ <br />
The URL can be used to link to this page
Your browser does not support the video tag.