Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />September 16, 2024 <br /> Facility Address: <br /> 7501 W ELEVENTH ST, Tracy <br /> Facility Name: <br /> Eleventh Street Chevron <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />OBSERVATION: A complete tank facility statement or a business plan has not been submitted in CERS . The last <br />submittal was made on 12/30/2022. <br />REGULATION GUIDANCE: (a)(1) On or before January 1, annually, each owner or operator of a tank facility subject to <br />this chapter shall file with the statewide information management system, a tank facility statement that shall identify <br />the name and address of the tank facility, a contact person for the tank facility, the total storage capacity of the tank <br />facility, and the location and contents of each petroleum storage tank that exceeds 10,000 gallons in storage <br />capacity. A copy of a statement submitted previously pursuant to this section may be submitted in lieu of a new tank <br />facility statement if no new or used storage tanks have been added to the facility or if no significant modifications have <br />been made. For purposes of this section, a significant modification includes, but is not limited to, altering existing <br />storage tanks or changing spill prevention or containment methods. (2) Notwithstanding paragraph (1), an owner or <br />operator of a tank facility that submits a business plan, as defined in subdivision (d) of Section 25501 , to the <br />statewide information management system and that complies with Sections 25503 , 25505 , 25505.1 , 25507 , <br />25507.2 , 25508 , 25508.1 , and 25508.2 , satisfies the requirement in paragraph (1) to file a tank facility statement. <br />CORRECTIVE ACTION: Immediately submit a complete and adequate tank facility statement or a business plan. <br />Submit proof of correction to the EHD. <br />This is (Minor) Violation. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br />finished on 9/18/2024 and replaces the initial checklist. Complete and submit a copy of the Return to <br />Compliance Certification form to the EHD with a statement documenting the corrective actions that have been or <br />will be taken for each violation, and any supporting paperwork, within 30 days of receiving the complete inspection <br />report. <br />Davinder K. Jutla, Owner <br />September 16, 2024 <br />(209) 616-3049Printed Name and Title: <br /> Date: Inspector: <br /> Paul Nso, EHS <br /> Inspector Phone: Received by: <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />FA0022384 PR0539001 SC001 09/16/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 6 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD