Laserfiche WebLink
II 11 Ii II 01' 1111 <br />IDENTIFICATION Ironman <br />LVP CONSTRUCTION <br />DESCRIPTION OF TEST SAMPLE <br />TEST METHOD CONDUCTED ASTM F1914 Test Method for Short-Term Indentation and Residual <br />Indentation of Resilient Floor Covering <br />P Professional <br />Testing <br />Laboratory <br />Inc. <br />TEST REPORT <br />DATE: 11-08-2019 Page 1 of 1 TEST NUMBER: 0261306 <br />CLIENT Happy Feet, International <br /> <br />PROCEDURE <br />A test sample is loaded with 140 lbs. on a presser foot .178 inches in diameter for 10 minutes. <br />After 60 minutes of recovery time the indentation is measured again and compared to the original <br />thickness of the sample. <br />TEST RESULTS <br />I RESIDUAL INDENTATION AT 140 Lbs. <br /> <br />0.004 Inch (3.60%) <br /> <br />APP ROVED BY: <br />This report is provided for the exclusive use of the clients whom it is addressed. It may be used In Its entirety to gain product acceptance from duly <br />constituted authorities. This report applies only to those samples tested and is not necessarily indicative of apparently Identical or similar products. <br />This report, or the namedf Professional Testing Laboratory, Inc., shall not be used under any circumna nce In advertising to the general public. <br />714 Glenwood Place Dalton, GA 30721 706-226-3283 Fax: 706-226-6787 protest@optllink.us