Laserfiche WebLink
SHEET NUMBER: <br />SHEET CONTENTS: <br />PROJECT NUMBER:PROJECT DATE: <br />CONSULTANTS: <br />Sacramento, CA 95827 <br />PH:(916) 455-6500 FAX:(916) 455-8100 <br />3090 Fite Circle, #104 <br />REVISIONS: <br />20-007 08-14-2020 <br />K12 Architects, Inc <br />DEVELOPER: <br />CONTRACTOR: <br />PROJECT: <br />Fast N <br />Easy <br />RIVER <br />ISLANDS <br /> 16460 GOLDEN VALLEY <br />PARKWAY <br />Lathrop, California 95330 <br />1 <br />Muhammad Bilal <br />10445 Chantel Lane <br />Stockton, CA 95212 <br />CONVENIENCE STORE AND <br />FUELING STATION <br />Parcel 1 <br />BUILDING DEPT. COMMENTS 10/4/21 <br />2 PLANNING DEPT REV 10/14/21 <br />3 BUILDING DEPT. COMMENTS 06/22/22 <br />3-25-2022 <br />4 BUILDING DEPT. COMMENTS 09/21/22 <br />5 FIRE DEPT. COMMENTS 10/19/22 <br />6 EHD-HAZMAT 12/12/22 <br />7 EHD-HAZMAT 02/03/23 <br />PROFESSIONAL SEALS: <br />8 ELECT MSB 06/28/23 <br />9 OWNER CHANGE 08/02/23 <br />10 WALK-IN COOLER DETAILS 10/13/23 <br />11 VEEDER-ROOT TLS-450 05/17/24 <br />DIESEL TANK SUMPS <br />FS5.0 <br />VENT DETAILS <br />6 <br />8 <br />FIBERGLASS CONTAINMENT SUMP TO TANK <br />COLLAR INSIDE AND OUT TO INSURE WATER <br />TIGHTNESS <br />42" MULTIPORT MANHOLE W/ LIQUID <br />TIGHT & VAPOR TIGHT FILL BOX <br />SUMP SHIELD <br />JUNCTION BOX <br />3/4" CONDUIT FROM ANNULAR <br />SPACE MONITOR JUNCTION BOX <br />SUMP PENETRATION BOOT <br />3/4" CONDUIT TO TURBINE <br />SUMP JUNCTION BOX <br />EXTRACTOR FITTING <br />WITH STL PLUG AT TOP <br />3" OVER 2" F.R.P. VENT LINE <br />2" BELLxMALE F.R.P. <br />THREADED ADAPTOR <br />USE OPW RISER SUPPORT BRACKETS (BRACELETS) <br />NOTES: <br />STEEL PLATE AT TANK BOTTOM <br />4" ALUMINUM FILL TUBE w/ POSITIVE <br />SHUT OFF DEVICE: INSTALL AT 95% <br />OF TANK CAPACITY <br />SCALE:3/4" = 1'-0" <br />DIESEL, FILL DETAIL <br />21 <br />10 <br />2" IN 3" CONDUIT PRESSURE LINE TO <br />TURBINE SUMP, PRIMARY LINE OPEN <br />FOR ELECT OR MONITOR WIRES. <br />LIQUID SENSOR INSTALL AT <br />LOWEST POINT TO ENSURE <br />LIQUID DETECTION AT <br />EARLIEST POSSIBLE MOMENT <br />TANK LEVEL MONITOR <br />79 <br />DOUBLE WALL <br />CONTAINMENT SUMP2 <br />9 <br />74 <br />BRAVO TEST PORT WITH HOSE <br />AND CONNECTION CAP <br />BRAVO FILL PORT <br />BRINE INTERSTITIAL SENSOR <br />26 <br />PERPENDICULAR PENETRATIONS OF CONTAINMENT SUMPS PREFERRED. 15° <br />MAXIMUM ALLOWABLE PENETRATION ANGLE. <br />USE SUMP PENETRATION BOOTS AT ALL PENETRATIONS OF SUMP. <br />ALL JUNCTION BOXES ARE TO BE PLACED WITHIN 1'-0" OF THE TOP OF SUMP. <br />1. <br />2. <br />3. <br />4. <br />4" TOP SEAL ADAPTOR & CAP <br />FUEL SWIVEL ADAPTOR <br />1" MIN. CLR TO SUMP <br />11 <br />18 <br />79 <br />10 <br />SCALE:3/4" = 1'-0" <br />DIESEL TURBINE SUMP PLAN VIEW <br />EXPLOSION PROOF JUNCTION BOX <br />SUMP SENSOR, INSTALL AT LOWEST <br />POINT TO ENSURE LIQUID DETECTION <br />AT EARLIEST POSSIBLE MOMENT <br />2"x18" FLEXIBLE CONNECTOR <br />MALE BY MALE SWIVEL <br />3"x2" BOOT WITH TEST PORT <br />2" SCH. 40 FRP. BELL x FEMALE <br />THREADED ADAPTER <br />1" CONDUIT TO INTRINSICALLY SAFE <br />GUTTER AT MONITOR CONTROL PANEL <br />(1 PER TANK) <br />3/4" CONDUIT TO TLM <br />79 <br />3" OVER 2" PRODUCT, <br />TO DISPENSERS <br />DOUBLE WALL <br />CONTAINMENT SUMP <br />TURBINE PUMP <br />2" BALL VALVE (MAKE HANDLE <br />ACCESSIBLE FROM GRADE) <br />LEAK DETECTOR <br />42 <br />3/4" CONDUIT FOR PUMP POWER <br />TO ELECT. PANEL -1 PER TANK <br />42" WATERTIGHT MANHOLE 9 <br />41 <br />37 <br />BRINE INTERSTITIAL SENSOR <br />VACUUM SENSOR AND HOSE80 <br />USE SIPHON JET PORT FOR <br />VACUUM GENERATION <br />5CHECK VALVE FOR <br />LEAK DETECTOR <br />79 <br />38 <br />81 <br />36 <br />TURBINE PUMP <br />JUNCTION BOX <br />PENETRATION BOOT <br />THIS PIPE TO FILL SUMP <br />3/4" CONDUIT TO ELECT. PANEL <br />(PUMP POWER) <br />1" CONDUIT TO INTRINSICALLY <br />SAFE GUTTER AT MONITOR <br />CONTROL PANEL (1 PER TANK) <br />3/4" CONDUIT TO FILL/ VAPOR <br />SUMP JUNCTION BOX <br />CONTAINMENT SUMP REDUCER, <br />FIBERGLASS REDUCER ON THE <br />OUTSIDE TO ENSURE WATER <br />TIGHTNESS <br />2"x18" FLEXIBLE CONNECTOR MALE <br />BY MALE SWIVEL <br />SCALE:3/4" = 1'-0" <br />DIESEL TURBINE CONTAINMENT - VIEW ELEVATION <br />38 <br />56 <br />42" WATERTIGHT MANHOLE9 <br />41 <br />SUMP SENSOR, INSTALL AT LOWEST <br />POINT TO ENSURE LIQUID DETECTION <br />AT EARLIEST POSSIBLE MOMENT <br />OPW WATERTIGHT FRP LID 34 <br />2 <br />79 <br />79 <br />BRINE SUMP INTERSTITIAL <br />MONITORING <br />FIBERGLASS CONTAINMENT SUMP <br />TO TANK COLLAR INSIDE AND OUT <br />TO INSURE WATER TIGHTNESS <br />BRAVO TEST PORT WITH <br />CONNECTION HOSE AND CAP <br />BRAVO FILL PORT <br />37 <br />55 <br />BARBED FITTINGS <br />VACUUM HOSE <br />36 <br />57 <br />79A <br />SCALE:3/4" = 1'-0" <br />DIESEL FILL - PLAN VIEW <br />EXTRACTOR FITTING <br />WITH TOP PLUG <br />3" F.R.P. VENT LINE TO VENT SUMP <br />SUMP PENETRATION BOOT <br />3" BELLxMALE F.R.P. <br />THREADED ADAPTOR <br />3"x12" FLEXIBLE CONNECTOR MALE <br />SWIVELxMALE <br />COUPLING <br />42" MULTIPORT MANHOLE <br />48"Ø DOUBLE WALL F.R.P. <br />CONTAINMENT SUMP WITH <br />REDUCING LID <br />55 <br />26 <br />33 <br />9 <br />6 <br />ELECT PENETRATION BOOT57 <br />27 <br />3" OVER 2" FOR <br />MONITORING AND <br />ELECT & VACUUM. <br />TO TURBIN SUMP. <br />56 <br />28 <br />7 <br />9 <br />VENT RISER <br />N.T.S.SCALE: <br />VENT SUMP SECTION <br />FOR NEW INSTALLATIONS SCALE:3/4" = 1'-0" <br />12 3'-0" MIN6"12" 12'-0" MINGRAD <br />E (TYP.)2'-0"NOTE:4'-6"2" FLEX 18"MIN.2" F.G. PIPE <br />30" MIN, ABOVE ROOF OF ANY <br />STRUCTURE WITHIN 10' <br />12" SQUARE <br />(TYP OF 2) <br />SUMP SENSOR <br />3" SQUARE <br />TUBE FRAME <br />50 <br />54 <br />PENETRATION BOOTS <br />52 <br />RACK SYSTEM FOR <br />5-PRODUCT87 GASBIO-DIESEL91 GAS20 <br />SEE 20/FS5.0 FOR GAS TANK <br />FOR UNLEADED GAS <br />PRESSURE VENTS <br />MANIFOLD THE 91 GAS TO THE <br />87 GAS, SEE 20/FS5.0 <br />OUR INSTALLATION IS SIMILAR TO THIS. WE ONLY HAVE <br />2 VENTS TO CONNECT, 87 UNLEADED AND 91 UNLEADED. <br />SEE DETAIL 12/FS5.0 <br />SUMP SENSOR NOTE <br />18 <br />SUMP LIQUID SENSORS: IF THESE ARE MOUNTED IN A SLEEVE OR TUBES, THAT ARE <br />TO BE CONSTRUCTED AND INSTALLED SO THAT THE SENSOR WILL HAVE THE <br />ABILITY TO DETECT A LEAK AT THE EARLIEST OPPORTUNITY. THE SLEEVE OR TUBE <br />SHALL NOT BE TIGHT AGAINST THE BOTTOM. CUT END AT AN ANGLE OR WITH <br />NOTCHES SO LIQUID IS ABLE TO GET TO THE SENSOR IMMEDIATELY. <br />SEE DETAIL 18/FS5 <br />SEE DETAIL 18/FS5.0 <br />NOTE: <br />THE TANK AND THE TANK SUMPS HAVE CALCIUM CHLORIDE IN THE <br />INTERSTITIAL SPACE. <br />CONTRACTOR TO LABEL FILL PORTS WITH TYPE OF FILL. <br />SCALE:N.T.S. <br />FOR DEPTH SEE <br />PIPING NOTES ON <br />FS2.1 <br />SLOPE <br />3" OVER 2" DOUBLE <br />WALL VENT PIPE <br />PENETRATION FITTING <br />45 BLACK <br />IRON ELBOW <br />2"x18" FLEX <br />CONNECTOR 54 <br />79 <br />SEAL ALL OPENINGS <br />WATER TIGHT <br />CONTRACTOR TO <br />PROVIDE RIGID PIPE TO <br />EA. VENT RECOVERY <br />MANIFOLD <br />SEE DETAIL 12,18/ FS5 FOR VENT <br />STACK <br />VENT SUMP 50 <br />1" ELECT CONDUIT <br />AT SUMP PENETRATION <br />BRAVO TEST PORT WITH <br />CONNECTION HOSE & CAP <br />NOTE: <br />THE DISPENSER SUMPS AND VENT SUMPS <br />HAVE PROPYLENE GLYCOL IN THE <br />INTERSTITIAL SPACE <br />CONTRACTOR TO LABEL FILL PORTS WITH <br />TYPE OF FILL. <br />ATMOSPHERIC <br />MANOMETER <br />HYDROSTATIC SUMP <br />SENSOR SEE DETAIL <br />18/ FS5.0 <br />PRIMARY MANOMETER <br />VENT LINE SUMP <br />KWIK FIT ELEC, <br />FITTING <br />PAINT ALL <br />EXPOSED <br />PIPING <br />2"x 1/2" NPT REDUCING TEE <br />PRESSURE VACCUM VENT VALVE <br />VALVE ENCLOSURE ASSEMBLY <br />2" THREADED VENT PIPE <br />J BOX, EPOXY ENCLOSED <br />CONNECTIONS <br />CANISTER OUTLET MUST BE 12'-0" MIN. <br />ABOVE GRADE. <br />CORD GRIP <br />2-PIN CONNECTOR OF CABLE. <br />ATTACHES TO CCVP VALVE <br />PIPE MANIFOLD <br />CANISTER SUPPORT <br />BRACKET AND FASTENERS. <br />SENSOR HOUSING <br />CANISTER ASSEMBLY <br />PRESSURE VACUUM <br />VENT VALVE BEYOND <br />2" THREADED VENT PIPE BEYOND <br />87 GAS91 GAS73 <br />36 <br />SCALE:N.T.S. <br />CANISTER AT VENT RISER <br />INLET PIPING KIT <br />VENT SUPPORT RACK <br />1" CONDUIT <br />VENT SUPPORT RACK DIESELE-857 <br />7 <br />7 <br />7 <br />7 <br />7 <br />7 <br />7 <br />79 <br />91 OMEGA FLEX, 2" X 18" <br />7 <br />91 <br />E85 <br />7 <br />11