My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER HEIGHTS
>
3400
>
3600 - Recreational Health Program
>
PR0360603
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2024 3:03:05 PM
Creation date
12/3/2024 3:02:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
WORK PLANS
RECORD_ID
PR0360603
PE
3611 - PUBLIC POOL/SPA - PRIMARY
FACILITY_ID
FA0001943
FACILITY_NAME
OCONNOR WOODS RETIREMENT COMMUNITY
STREET_NUMBER
3400
STREET_NAME
WAGNER HEIGHTS
City
STOCKTON
Zip
95209
APN
08039014
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\ymoreno
Supplemental fields
Site Address
3400 WAGNER HEIGHTS STOCKTON 95209
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:••( <br />/ / <br />E. k e,c ,rc,))4Lion (co o liOtied) <br />Flowmeter properly located with 10 pipe diameters of straight pipe in front and 4 pipe <br />diameters in back of the flow meter and be capable of easy inspection. <br />Pressure gauges on influent and effluent lines with 10 pipe diameters in front and 5 pipe <br />diameters in back of all gauges and be capable of easy inspection. <br />vacuum gauge on suction type filters. <br />Hair and lint strainer on suction side of pump. <br />F. Water Supply (2-9035) <br />Permanently installed line from an approved source. iify ic,e <br />Air gap, vacuun breaker - installed beyond last inlet valve and at least 6 in. above <br />pool coping,-er-deubi-e-ateck-vaive-needed, Ne-tf4p-hetaf4-pgesen;,- <br />uvie .tau ruiatct"? fr-z-Ch-4 rumt ‘,rtike, <br />G. Bottom Drain (2-9013, 9033, and 9042) <br />Hydrostatic device if needed for high water table. <br />Gate valve. Accessible for operation and repair. Labelled. Not in deck. <br />Cover grates with openings max. 1/2 in. and removable with tools. <br />H. Cleaning System (2-9044) <br />1. Vacuum or jet type with backf low protection. <br />I. Electrical (2-9019, 3-680-6 and 20) <br />Underwater light with CFI (15 volt system also require OFT) and deck area lighting <br />if pool used at night. Overhead lighting may substitute for the underwater lights. <br />Receptacle outlets located at least 10 ft. from inside wall of pool. If within <br />20 ft., protected by GFI. 0/1 <br />J. Steps, Ladders, and Stairs (2-9015) <br />Required at shallow end if over 2 ft. deep and at deep end if over 4 1/2 ft. Ladders <br />require 2 handrails. <br />Required at each side at 100 ft. increments if pool wider than 30 ft. <br />Ladders min. 3 in. or max. 5 in. from wall. <br />Steps and step holes in walls: min. tread 5 in., min. width 14 in., readily cleanable, <br />nonskid treads. <br />Each stair step shall be uniform with a min. tread of 12 in. except convexly curved top <br />step is 18 in., max. risers 12 in. <br />Rail extending from deck to top of lowest step, min, height of 28 in. )above the deck at <br />the pool edge of the coping. <br />\., -f- r.c/4 <br />si : • - : t„. - ,- <br />w <br />K. Handholds (2-9016) <br />1. Located not more than 9 in. above water level. <br />2. Bull-nosed coping or cantilevered decking that is not over 2 1/2 in. thick for the 1 <br />to 2 in. overhang. <br />L. Permanent Markings (2-9014) <br />Straight line of slip resistant tile, 4 in. wide, contrasting color, required across bottom <br />of pool at 4 1/2 ft. depth except if pool's max. depth is 5 ft. <br />Depth markers, min. 3 in. in height of contrasting color required at or above water level <br />at max., min., and slope break depths and at each end and spaced at 25 ft. intervals. <br />Pool width greater than 20 ft.: Slip resistant depth markers required on edge of deck. <br />Depth markers to indicate water depth accurate to nearest 6 in. <br />Max. width of slip resistent line markings is 12 in. <br />No design on bottom or sides resembling a huaan form. <br />M. Perimeter Overflow (2-9042)(pool area over 5000 sq.ft.) <br />Min. 75% of required flow. <br />Channel min. 3 in. deep; bottom width of channel min. 3 in.; opening beneath coping into <br />channel min. 4 in. <br />Channel lip max. 12 in. below top of deck; rounded lip edge 1 to 2 1/2 in. thick at top 2 in. <br />Channel outlet min. 21/2 in. diameter, max. 15 ft. apart and channel sloped min. 1/4 in./ft. <br />to outlets. <br />Channel drain grates 1 1/2 times area of outlet pipe. <br />Surge tank storage min. 1 gal./sq.ft. of pool surface. <br />Automatic make-up water with manual override for maintaining pool water level. <br />N. Decks (2-9018) <br />Min. 4 ft. nonslip and nonabrasive deck around pool and rear of diving board and slides. <br />Coping shall be slip resistant. <br />Deck sloping at least 1/4 in./ft. away from pool. <br />Deck drains, if provided, shall have 4 in. drain inlet, max. 400 sq.ft./drain and drains <br />spaced max. 25 ft. apart. <br />O. Fencing and Gates (2-9024) <br />fence, wall, building, enclosure min. of 4 ft. high with openings, holes, gaps not exceeding 4 in. <br />Gate with a self-closing and self-latching device located not less than 3 1/2 ft. above deck. <br />All items on page completed