Laserfiche WebLink
-sr SAN <br />Greorrcsc <br />JOAQUIN <br />coU NT Y <br />tyre,vec here. <br />Environmental Health Department <br />Time In: 11.15 am <br />Time Out: 11:49 am <br />Swimming Pool Official Inspection Report <br />Name of Facility: OCONNOR WOODS RETIREMENT COMMUNITY Date: 06/18/2019 <br />Address: 3400 WAGNER HEIGHTS , STOCKTON 95209 <br />Owner/Operator: OCONNOR WOODS HOUSING CORP Telephone: (209) 956-3400 <br />Program Element: 3611 - PUBLIC POOUSPA - PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#3 Safety Signs <br />OBSERVATIONS: Site address is not provided. Provide by today. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Both light bulbs in the pool are not functioning. Replace/repair by today. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Restrictive valves are missing in both skimmers. Install by today. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />#27 Pool Equipment Room <br />OBSERVATIONS: There leaves and a fig tree growing in the equipment area. Clean by today. <br />CALCODE DESCRIPTION: Pool operator shall keep ancillary facilities well maintained. (CCR 65535) All filters, valves, pumps, strainers <br />and equipment shall be readily accessible for repair and replacement. (CBC 3123B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 65 gpm Chlorine: 3 ppm Temp: ° F <br /> <br />Cyanuric acid: 40 ppm pH: 7.4 Combined chlorine: 0 ppm <br />FA0001943 PR0360603 SC001 06/18/2019 <br />EH D 36-01 Rev. 06/30/15 <br /> <br />Page 1 of 2 <br /> Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 I F 209 464-0138 I wvvw.sjcehd.com