My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2026 10:13:01 PM
Creation date
1/6/2025 4:11:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0505264
PE
2361 - UST FACILITY
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1501 N JACK TONE RD RIPON 95366
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
503
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IS Outlook <br /> RE:1501 N Jack Tone Rd-Notification <br /> From Tara Velleux<Tara.Velleux@jfpetrogroup.com> <br /> Date Thu 5/15/2025 11:18 AM <br /> To Saetern,Kristina Gaen[EHD]<ksaetern@sjgov.org> <br /> Cc Joey Cupp<joey.cupp@pilottravelcentem.com>;Miluska Cioffi<Miluska.Cioffi@pilottravelcenters.com>;Gregory Smith<Gregory.Smith@jfpetrogroup.com>;Robert Sills<Robert.Sills@jfpetrogroup.com> <br /> Kristine, <br /> I wanted to provide you with the notes from the work order that describe the resolution of the issues you witnessed while you were on site for the Monitor Certification. Everything was resolved on site <br /> and positive shutdown was confirmed and all testing passed. Once test reports are QC'ed,we will submit through proper channels. <br /> 05113 Checked in with site manager Jay before beginning work.Here today to perform the Annual Monitoring Certification for 2025.Kristine from San Juaquin Environmental Health was on site to witness today's testing. <br /> Techs began by testing hydrostatic testing of all spill buckets.Tank 1-Diesel spill bucket failed hydro test initially.Techs removed the fill adapter and EBW drain valve.Lots of debris was found at the bottom of the drain <br /> valve and O-Ring causing the valve not to fully shut.Debris was removed and all components were reinstalled propedy.Retested the spill bucket for 1 hour and got passing results.1-hour extra time was spent <br /> troubleshooting,repairing and retesting of the spill bucket.All spill buckets passed hydro testing after repairs. <br /> While testing liquid sensors in the Auto UDC's we found that the 87 STP was not shutting down when the UDC sensors were in alarms.Checked programming and verified that all Auto UDC and sump liquid sensors <br /> were programmed to shut down the 87 STP.The 87 STP Sump sensor was tested and confirmed positive shutdown was not operational.Further troubleshooting was needed.Hook Signals would turn on the 87 Relay <br /> and STP,but VR would not interrupt the circuit when a sensor was in alarm.Believe that the issue may be due to a bad connection on the Output Relay Module board in#9 slot.Upon opening the Veeder-Root Door 1 <br /> found the wiring connections of the Output Relay Module for Slot 4 91 STP to be loose and appeared to have melted the plastic around the terminations.Found that due to Output Relay Module Slot Location for 87 STP <br /> we needed to shut down the entire site to troubleshoot.The truck Diesel side was closed at that time to further investigate.Archived Veeder-Root programming and removed power from the TLS-350.Removed the <br /> Output Relay Board and visually inspected the fuses.Fuses appeared to be in good condition.Reset the board into Output Relay Module slot 9 and re terminated all connections going into that board.Restored power to <br /> the TLS-350 and we retested liquid sensors and positive shut down for the 87 STP.Positive shutdown was now operational for 87 STP but we found the 91 STP no longer turning on.This further delayed testing.With a <br /> hook handle lifted,checked voltage coming into the Auto TLS-350 and found 0 volts when metering the Normally Open"NO"and Common"C"contact.Traced back the"C"contact wiring through the electrical conduit <br /> and chase boxes to the Bio TLS-350 Output Relay Module Board.Confirmed 120volts at the"C"contact while the"NO"contact going to the Auto TLS-350 had 0 volts.Manually Tested the Output Relay for 91 STP while <br /> testing with continuity at the"NO"and"C"contacts.Archived Bio Veeder-Root and removed power.Removed the Output Relay Board and found the fuse for the 91 STP position had blown.Replaced blown fuse with a <br /> spare located on that board and reinstalled.Confirmed 91 STP issue to be due to the loose wiring causing the Output Relay fuse to blow in the TLS-350 Bio Veeder Root.With power restored to both VR's I confirmed <br /> voltage for 91 STP was at 120 and STP now operable.Approximately 3 extra hours were spent troubleshooting the 87 Positive Shutdown and 91 STP issues. <br /> After issues were addressed,we continued with testing.All liquid sensors,hydro sensors,vacuum sensors,sensors out,and positive shutdown were confirmed operational and passed testing. <br /> Tested total of 6 Line Leak Detectors.Tank 2-Truck Diesel VMI 99-LD2000 failed to detect the 3.00 GPH leak rate initially.Made one adjustment to the MILD and retested.Testing passed after adjustment was made.0.5 <br /> hours extra time was spent adjusting and retesting the MLD.All Line Leak Detectors passed the test. <br /> "L 11:Sensor Out"for 91 Annular Sensor on AutolTruck TLS-350 and"s2:Vacuum Warning"for RV 19,20 Prod vacuum zone on the Bio TLS-350 was active at time of arrival.Site has had recent open work orders for both <br /> alarms that may need follow up.While on site performing testing,we tested sensors and confirmed they were operational at this time.Alarms self-cleared but if they return site is to create service ticket to further <br /> investigate.All alarms caused while on site had cleared after work was completed.Sensors confirmed in proper locations and locked.Environmental Checklist Completed with on duty site manager. <br /> Thank you, <br /> Tara <br /> Tara Velleux <br /> CDCompliance Lead <br /> 9595 Lucas Ranch Rd.,#100,Rancho Cucamonga CA 91730 <br /> 888-972-7581 1 Q 617-817-5319 <br /> jt?NESCUVEYr,RgI,R,INC. Tara.Velleux@jfpetrogmup.com <br /> ✓ 855JFPETRO 12417 Service 800-286-4133 <br /> jfpetrogroup.com I W]fpetroparts.com <br /> ! Sd+�wtl <br /> The mrormaue„i„mia aecwmo mesaage is legallr paNlegea ana ponraepual aoaer applkable law a�a is mteaea eery ror one ase erne <br /> individual or eerily nametl above.If you are not IM1a inlentletl reGpienl of ikls message,you era M1ereby notirietl IM1at any use,tllaMbalon, <br /> copying,err tlisGosure or iM1is cwnmunicatlan is proM1ibitetl.It you M1eve receivetl IM1is communicelion in error,please nanfy JF Petroleum <br /> Group at 838-]555 or return ibe email to olkca�rpatrogmuPwin,antl purge iM1e transmissbn immetlialely wXM1oul making any <br /> copy err tli.ffibalribWan. <br /> From:Saetern,Kristina Gaen[EHD]<ksaetern@sjgov.org> <br /> Sent:Tuesday,May 13,2025 4:55 PM <br /> To:Tara Velleux<Tara.Velleux@jfpetrogroup.com>;Robert Sills<Robert.5ills@jfpetrogroup.com> <br /> Cc:Joey Cupp<joey.cupp@pilottmvelcenters.com> <br /> Subject:1501 N lack Tone Rd-Notification <br /> CAUTION:EXTERNAL <br /> Hello, <br /> The monitoring system certification was partially witnessed.During the time of inspection,the oveday/relay switch was not working properly affecting the positive shut down on the gasoline and diesel TLS 350 panel.In <br /> addition,the T1 diesel spill container failed.As a reminder,please provide the Environmental Health Department(EHD)a notifications for all repairs by emailing the 1Ag&jgov.org. <br /> Permits must be approved by the EHD prior to beginning work for non-emergency repairs.Permit applications for emergency repairs must be submitted within one(1)business day of the repair.Emergency repairs are <br /> unplanned repairs relating to monitoring and release detection only. <br /> Best, <br /> Kristina Saetern <br /> Environmental Health Specialist <br /> San Joaquin County Environmental Health Department <br /> 1868 E.Hazelton Avenue Stockton,CA 95205 <br /> P:(209)616-3045 1 E:ksaeternOsjgov.org <br /> www.sjggwM EHD <br />
The URL can be used to link to this page