PE
2371 - UST FACILITY - 1702 COMPLIANT
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
AVE
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1812 Coley AVE Escalon 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Spill Container Testing Report Form <br /> 6. SPILL CONTAINER DETAILS <br /> Test Method Developed by ❑ Manufacturer O Industry Standard ❑ Professional Engineer <br /> Test Type ❑ Pressure ❑ Vacuum 121 Hydrostatic <br /> Tank ID UG0100001 <br /> Spill Container Manufacturer: Phil-Tate <br /> Method of Cathodic Protection IZI Nonmetallic ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic <br /> ❑ Other ❑ Other ❑ Other ❑ Other <br /> Is the spill container minimum O Yes ❑ Yes ❑ Yes ❑ Yes <br /> capacity five gallons excluding ❑ No* ❑ No* ❑ No* ❑ No* <br /> riser volume? <br /> 0 Drain ❑ Drain ❑ Drain ❑ Drain <br /> Method to keep spill container ❑ Pump ❑ Pump ❑ Pump ❑ Pump <br /> empty ❑ Other ❑ Other ❑ Other ❑ Other <br /> Spill Container Test Results 0 Pass ❑ Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> Tank ID <br /> Spill Container Manufacturer: <br /> Method of Cathodic Protection ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic <br /> ❑ Other ❑ Other ❑ Other ❑ Other <br /> Is the spill container minimum ❑ Yes ❑ Yes ❑ Yes ❑ Yes <br /> capacity five gallons excluding ❑ No* ❑ No* ❑ No* ❑ No* <br /> riser volume? <br /> ❑ Drain ❑ Drain ❑ Drain ❑ Drain <br /> Method to keep spill container ❑ Pump ❑ Pump ❑ Pump El Pump <br /> empty ❑ Other ❑ Other ❑ Other ❑ Other <br /> Spill Container Test Results ❑ Pass ❑ Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> 8. COMMENTS <br /> Describe all answers marked "Other," "No," or "Fail" and each proposed remedy. <br /> * Mark here if: <br /> ❑ Spill containers do not have a minimum capacity of five gallons and require replacement. <br /> Additional copies of this page may be attached. <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.