My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR2400480
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
3457
>
2900 - Site Mitigation Program
>
SR2400480
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2026 11:25:20 AM
Creation date
1/16/2025 4:08:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
SR2400480
PE
2900 - Site Mitigation Program
STREET_NUMBER
3457
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17702078
CURRENT_STATUS
Active
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3457 S AIRPORT WAY STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Casey Sanders - 2 - 25 September 2023 <br /> Samples will be taken in accordance with the July 2015 DTSC/RWQCB Advisory for <br /> Active Soil Gas. Each sample take will be collected in a laboratory supplied, batch <br /> certified 1-liter SUMMA canisters, with new tubing between each sampling to avoid <br /> cross contamination. Duplicate samples will also be collected at a rate of at least 1 per <br /> sample event or 10 percent, whichever one being greater. Lastly, the SUMMA canisters <br /> will be shipped off to a laboratory for analysis of helium leak check compound and <br /> VOCs using ASTM Modified Method D-1946 and U.S. Environmental Protection Agency <br /> (USEPA) Method TO-15. <br /> Indoor and Outdoor Air Sampling <br /> To assess indoor air quality, 12 samples will be co-located with the sub-slab samples in <br /> Buildings 2, 3, 4, 6, and 9. Windows will be closed when indoor air samples are being <br /> taken, unless there is no air conditioning in the buildings during summer months. In the <br /> winter, indoor air temperatures will be maintained to around 65' F when samples are <br /> being collected. Three ambient air samples will be taken in total, upwind, downwind, <br /> and crosswind of the buildings. Ambient air samples will be collected over an 8-hour <br /> period and corresponding to the indoor air sample locations. <br /> Indoor air samples will be taken in accordance with the July 2015 DTSC/RWQCB <br /> Advisory for Active Soil Gas Investigations. 6-liter SUMMA canisters will be inside <br /> buildings at the height of 3 to 5 feet, and flow controllers will be set for approximately 8 <br /> hours for the sample period. Prior to sampling, canisters will have more than 25 inches <br /> of mercury gauge pressure and down to 1 to 10 inches at the end of the 8-hour <br /> sampling period. These SUMMA canisters will also be shipped off to the laboratory to <br /> be analyzed for VOCs using USEPA Method TO-15 selective ion monitoring (SIM). <br /> Soil Gas Sampling <br /> Up to 18 soil gas samples will also be collected across 9 locations in the areas <br /> surrounding Buildings 2, 3, 4, 6, and 9. To reach the subsurface, concrete coring will be <br /> conducted on each sampling location as needed. Soil gas probes will be installed as <br /> dual nested wells at the depths of 5 feet and 15 feet below ground surface and sampling <br /> probes will be created with steps similar to the sub-slab soil gas probes. <br /> Similar to other samplings, soil gas samples will be collected in accordance with the <br /> July 2015 DTSC/RWQCB Advisory for Active Soil Gas Investigations. Samples will be <br /> shipped off in 1-liter SUMMA canisters and will be analyzed for helium and VOCs by <br /> ASTM Modified Method D-1946 and USEPA Methods TO-1 5. <br /> Comments <br /> Central Valley Water Board staff concurs with the proposed sampling methods and <br /> locations, and sampling should be conducted as proposed. Please provide us with the <br /> field sampling schedule when it becomes available to provide us with the opportunity to <br /> observe the work. A Vapor Intrusion Assessment Report should be submitted to this <br /> office no later than 1 March 2024. In addition, please upload the relevant information <br />
The URL can be used to link to this page
Your browser does not support the video tag.