SCOPE OF WORK <br /> Q REPLACED S7 VACUUM SENSOR ON THE 87 TANK <br /> ti m <br /> / PART#VR-330020-063 � <br /> © REPLACED S3 VACUUM SENSOR ON THE 87 TANK V 0 <br /> w y <br /> PART#VR-857280-100 t U e <br /> H N x <br /> 03 REPLACED DUAL POINT HYDROSTATIC ANNULAR U >w <br /> SENSOR ON THE 91 TANK. . <br /> d' OUr1 � pU2 <br /> PART#VR-794380-303 <br /> ® g Q n # O <br /> mar _ Q = C) Ja SwF <br /> w r z Qx <br /> LL A 0 O LL J <br /> momx W <br /> I `ryT / VEEOER FOOT RS T50 1 Al _ AaL�OAYSA WEEKAOAT <br /> tll I <br /> yA BO GAL L Y <br /> ( (1 )(2) 62 ( a <br /> pE�T _ <br /> i ® 20.000 GAL ) LU <br /> I ® � <br /> ®` SHEETINDEX w <br /> ® 1 ❑ F-O SITE PLAN Q <br /> y _I F-1 VACUUM SENSOR AND ANNULAR SENSOR <br /> fE <br /> III m m I3010 mo PROJECT DATA <br /> PROJECT NAME: SENSOR RE PLACEMENT a <br /> 4 I I_I - PROJECTADDRESS: 10858 TRINITY PARKWAY STOCKTON CA 95219 2 <br /> r ( PARCEL NUMBER: XXXX-XXX-XXXX-X UU <br /> FACILITY OWNER CHEVRON PRODUCTS COMPANY of <br /> II a lI2I i"° PROPERITY OWNER: P.O.BOX 60D4,SAN RAMON,CA.94583 <br /> e Ill I BUILDING CODES: 2019 CBC: CALIFORNIA BUILDING CODE <br /> 2019 CMC: CAUFORNIA MECHANICAL CODE <br /> 2019 CPC CALIFORNIA <br /> : CALFORNA PLUMBING CODE <br /> ❑ ❑ 2019 DEC. CAL FORNA ELECTRICAL CODE a <br /> my 2019 CFC: CALIFORNIA FIRE CODE <br /> �p 2019 CALIFORNIA FIRE CODE FOR BUILDING CONSERVATION o44 <br /> a IO O I T 2019 NFPA 30&018 NFPA 30A520172019 CAL FORNIA EFCIENCYDNFPA 70 <br /> I I <br /> C�l <br /> C) <br /> F * >- <br /> Q Q LLO <br /> a of < <br /> Z cr- <br /> Q Do Z Z <br /> J 0, RO <br /> a O F- Y <br /> GENERAL NOTES VICINITY MAP Lli DO <br /> � z LO <br /> 1.ALL WORK TO BE COMPLETED IN ACCORDANCE OF CURRENT AND APPLICABLE BUILDING/ 6. CONTRACTOR RESPONSIBLE TO COORDINATE ALL INSPECTIONS WITH FIRE AND LOCAL AIR CONTROL DISTRICTS - U) U) <br /> ELECTRICAL CODES,FIRE CODES,STATE WATER BOARD AND LOCAL CUPA REQUIREMENTS AS 7. CONTRACTOR RESPONSIBLE TO CALIBRATE AND SUBMIT"PLACE IN SERVICE"NOTIFICATION TO GOVERNING <br /> WELL AS CARS AND LOCAL AIR CONTROL DISTRICTS. WEIGHTS AND MEASURES DEPARTMENT FOR METER CAUBRA71ON OF ANY MEASURING DEVICES. 19El" DRAWN BY:DIEGO <br /> 2.IF ANY UNDERGROUND WORK IS BEING COMPLETED,CONTRACTOR IS RESPONSIBLE FOR 8. CUSTOMER REQUIRES A PRE-TEST OF THE VAPOR RECOVERY SYSTEM PRIOR TO PLACING IN SERVICE.TESTING TC REVIEWED BY: <br /> CONTACTING AND COORDINATING UNDERGROUND SERVICE ALERT(USA)AND MARKING THE BE PERFORMED AND OR COORDINATED BY CONTRACTOR ON BEHALF OF CHEVRON. -N- DATE:3/17/25 <br /> SITE IN ACCORDANCE OF DIG ALERT REQUIREMENTS-DIAL 811 ,(800)227-26DO OR FILE ELECTRONICALLY 9. CONTRACTOR TO COORDINATE ANY INSPECTIONS WITH GOVERNING AGENCIES INCLUDING INSPECTIONS OF I JOB NO:616680 <br /> AT HTTPSJ/ WWW.DIGALERT.ORG/ FUEUNG SYSTEM BY CUPA/FIRE AS WELLAS COORDINATION OF A FINAL WALKTHROUGH WITH THE <br /> 3.ALL WORK IS TO BE COMPLETED BY A LICENSED AND INSURED CONTRACTOR WITH THE STATE OF CAUFORNIA CHEVRON PROJECT MANAGEMENT TEAM FOR A FINAL QAQC INSPECTION PRIOR TO OPENING. SHEET <br /> 4.ALL WORK IS TO BE COMPLETED BY COMPETENT AND CERTIFIED TECHNICIANS)WITH CURRENT AND APPLICABLE 1D. ALL WORK AREAS TO BE SAFELY BARRICADED.WORK TO BE COMPLETED SAFELY FOLLOWING INDUSTRY <br /> ICC CERTIFICATIONS AS WELL AS REQUIRED MANUFACTURER TRAINING)CERTIFICATIONS. STANDARD API AND OSHA REQUIREMENTS <br /> 5.NO ADDITIONAL ELECTRICAL LOADS ARE BEING INTRODUCED AS PART OF THIS UPGRADE)INSTALLATION. 11.CURRENT EXISTING V EEDER ROOT SOFTWARE 336.01,ISO 1.06 TO REMAIN <br /> �, _ FO <br />