COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2026 8:39:33 PM
Creation date
1/22/2025 1:36:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0521537
PE
2371 - UST FACILITY - 1702 COMPLIANT
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2615 W GRANT LINE RD TRACY 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage lank <br /> Secondary Containment Vesting Report Form <br /> 8. SUMP/UDC TEST <br /> Test Method Developed by ❑ Manufacturer 0 Industry Standard ❑ Professional Engineer <br /> Test Type ❑ Pressure ❑ Vacuum ❑ Hydrostatic <br /> Test Equipment Used: <br /> Sump/UDC ID #1/2 UDC #3/4 UDC #5/6 UDC #7/8 UDC <br /> Sump Manufacturer Ameron Ameron Ameron Ameron <br /> Sump Depth (inches) 23" 23" 23,E 23" <br /> Sump Bottom to Top of <br /> Highest Pipe Penetration <br /> 14" 14" 14" 14" <br /> (inches) <br /> Test Start Time 0 mins 0 mins 0 mins 0 mins <br /> Initial Reading 0 0 0 0 <br /> Test End Time 30 mins 30 mins 30 mins 30 mins <br /> Final Reading 0 0 0 <br /> Change in Reading 0 0 0 0 <br /> Pass/Fail Criteria Pass Pass Pass Pass <br /> Tightness Test Results 712 Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Sump/UDC ID #9/10 UDC #11/12 UDC 87 STP Sum <br /> Sump Manufacturer Ameron Ameron Total Containment <br /> Sump Depth (inches) 23" 23" <br /> Sump Bottom to Top of <br /> Highest Pipe Penetration 14" 14" 23" <br /> (inches) <br /> Test Start Time 0 mins 0 mins 0 mins <br /> Initial Reading 0 0 0 <br /> Test End Time 30 mins 30 mins 30 mins <br /> Final Reading 0 0 0 <br /> Change in Reading 0 0 0 <br /> Pass/Fail Criteria Pass Pass <br /> Tightness Test Results 0 Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ® Pass ❑ Fail <br /> Additional copies of this page may be attached. <br /> All tests marked "Fail"and any repairs made before or during the tightness test must be described in <br /> the COMMENTS section. <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.