My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1097
>
2300 - Underground Storage Tank Program
>
PR0231497
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2026 12:02:53 PM
Creation date
1/23/2025 10:02:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231497
PE
2361 - UST FACILITY
FACILITY_ID
FA0000279
FACILITY_NAME
ESCALON MINI MART
STREET_NUMBER
1097
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
ESCALON
Zip
95320
APN
22510001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1097 YOSEMITE AVE ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"O"WO <br /> Measure&record"A"and"Z,"and then peform the following calculation: <br /> "A" 157 " Drop tube seal surface to the bottom of the tank <br /> -(subtract) <br /> "Z" 53.5 " Upper drop tube flange to the edge of the upper tube adapter <br /> -(subtract) <br /> 4.5" Reference offset <br /> _(equals) <br /> 99 " Final shutoff volume height <br /> Locate the final shutoff volume <br /> height on the tank chart <br /> Use the tank chart provided by the tank provided by the tank <br /> manufacturer to record and calculate the following: manufacturer,and record the <br /> 6575 Final shutoff volume closest corresponding volume. <br /> gal <br /> (divide by) <br /> 7006 gal Actual tank capacity <br /> X(muliply by) <br /> 100 <br /> a =(equals) If the final shutoff volume <br /> 0 o percentage is 95%or less,the <br /> 93.8% % Final shutoff volume percentage installation conforms to FFS and <br /> industry recommended practices. <br /> 7006 ga I Actual tank capacity <br /> The final Shutoff Volume Percentage may <br /> -(subtract) be greater than 95%as long as the ullage <br /> 6575 gad I Final shutoff volume volume remaining is greater than or <br /> _(equals) equal to 250 gallons,so that"...none of <br /> the fittings located on the top of the tank <br /> 431 gall Ullage volume remaining are exposed to product due to <br /> overfilling,"according to EPA 40 CFR Part <br /> 280. The installation must also meet all <br /> applicable regulatory requirements,and <br /> must be acceptable to the Authority <br /> Having Jurisdiction(AHJ). <br />
The URL can be used to link to this page
Your browser does not support the video tag.