My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1403
>
2300 - Underground Storage Tank Program
>
PR0231995
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2026 7:36:44 PM
Creation date
1/30/2025 10:21:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0231995
PE
2361 - UST FACILITY
FACILITY_ID
FA0006438
FACILITY_NAME
UNITED #5446
STREET_NUMBER
1403
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12323246
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1403 W COUNTRY CLUB BLVD STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> —COUNTY <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> United #5446 11403 W COUNTRY CLUB BLVD, STOCKTON October 29, 2025 <br /> 78 2650(e), 2652 2030077-Owner/Operator notified/prepared report upon discovery of unauthorized ❑OUT ❑ R ❑COS <br /> release (TCR 9d) <br /> 79 2717.1(g) 2030045- Red Tag information is legible and has not been removed or tampered ❑OUT ❑ R ❑COS <br /> with <br /> 80 2717.1(f); HSC 25292.3 2030044- Facility did not deposit/allow deposit of petroleum or a hazardous ❑OUT ❑ R ❑COS <br /> (c) substance into a red tagged UST <br /> 81 25292.3(c)(1)(C) 2030079- Facility did not dispense petroleum or a hazardous substance from a ❑OUT ❑ R ❑COS <br /> UST that has been red tagged <br /> 82 2670(b)(e)(f), 2671 2030063- Facility is in compliance with temporary closure requirements ❑OUT ❑ R ❑COS <br /> 83 25298(c); CCR 2670, 2030038- UST system properly closed and complies with permanent closure ❑OUT ❑ R ❑COS <br /> 2672 requirements <br /> 84 25392.4(d), 25292.5(c) 2030066- Repaired/retested any leaks found when ELD testing a UST within 1,000 ❑OUT ❑ R ❑COS <br /> feet of a public water well <br /> 85 2631(a); HSC 25290.1(c) 2060027-Tank system primary containment is constructed, operated, and ❑OUT ❑ R ❑COS <br /> maintained product-tight. <br /> 86 2631.1, 2660(m) 2060024- UST system is made of or lined with materials that are compatible with ❑OUT ❑ R ❑COS <br /> the substance stored. <br /> 87 2631(c), 2662(d) 2060021 -Striker plate installed and positioned correctly. ❑OUT ❑ R ❑COS <br /> 88 2631(b&d), 2666(b&e) 2060007-Primary and secondary containment designed and constructed to an ❑OUT ❑ R ❑COS <br /> engineering specification. <br /> 89 25290.10) 2060008- Enhanced leak detection testing performed before the tank is placed in ❑OUT ❑ R ❑COS <br /> use <br /> 90 2666(b)(2) 2060029-SW piping has been upgraded to continuously monitored DW piping ❑OUT ❑ R ❑COS <br /> when replacement or repair needed <br /> 91 25291(e) 2010-Administration/Documentation-General ❑OUT ❑ R ❑COS <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑ R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 3 2632(d)(1), 2634(d) 2010013- Facility has submitted a complete and accurate UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan submitted to CERS is not current. <br /> -The monitoring plan lists the overfill prevention method for the used oil tank as audible visual. A universal used oil drop <br /> tube was installed 07/21/25. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br /> (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a Repeat(Class 2)Violation. <br /> 50 2635, 2637.1, 2665, 2712 2060020- Spill buckets meet requirements, have been tested as required, and records kept <br /> for 36 mths (TCR 9a) <br /> OBSERVATION: The technician stated that the 91 direct-bury spill container failed when tested due to the drain valve. <br /> REGULATION GUIDANCE: All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up. <br /> CORRECTIVE ACTION: The technician on site replaced the drain valve, re-tested the spill container and it passed. <br /> This was corrected on site. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 4 of 6 FA0006438 PR0231995 4570130 10/29/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.