My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILCOX
>
2720
>
2800 - Aboveground Petroleum Storage Program
>
PR0540837
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 2:27:23 PM
Creation date
2/24/2025 2:34:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0540837
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0023343
FACILITY_NAME
California Highway Patrol - Stockton
STREET_NUMBER
2720
STREET_NAME
WILCOX
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
8710076
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2720 Wilcox RD Stockton 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />February 19, 2025 <br /> Facility Address: <br /> 2720 Wilcox RD, Stockton <br /> Facility Name: <br /> California Highway Patrol - Stockton <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />necessarily that all the sensors are functioning appropriately. The 2024 annual inspection checklist did not have an <br />alarm history attached. It could not be demonstrated that the interstitial sensors have been tested for functionality for <br />the 12,000-gal gasoline tank and 4,000-gal diesel tank <br />- Annual tank inspections were not conducted for the 250-gal waste oil tank. No record of liquid sensing devices for the <br />waste oil tank have been tested for functionality. <br />REGULATION GUIDANCE: 112.8(c)(8)(v) You must regularly test liquid level sensing devices to ensure proper <br />operation. <br /> CORRECTIVE ACTION: Liquid level sensing devices must be installed in accordance with CFR 112.8 and shall be <br />regularly tested to ensure proper operation. Immediately conduct all necessary testing of 250-gal waste oil tank, <br />12,000-gal gasoline tank, 4,000-gal diesel tank liquid level sensing devices to ensure proper operation, submit proof of <br />testing to the EHD. <br />This is (Class 2) Violation. <br />Code of Fed Regulations 112.20(e) 4010044 - Substantial Harm Criteria certification maintained at the facility as <br />required. <br />OBSERVATION: The facility failed to complete and maintain (at the facility) the Substantial Harm Criteria certification <br />form. The Substantial Harm Criteria in the SPCC Plan was not signed. <br />REGULATION GUIDANCE: 112.20 (e) If the owner or operator of a facility determines pursuant to paragraph (a)(2) of <br />this section that the facility could not, because of its location, reasonably be expected to cause substantial harm to <br />the environment by discharging oil into or on the navigable waters or adjoining shorelines, the owner or operator shall <br />complete and maintain at the facility the certification form contained in appendix C to this part and, in the event an <br />alternative formula that is comparable to one contained in appendix C to this part is used to evaluate the criterion in <br />paragraph (f)(1)(ii)(B) or (f)(1)(ii)(C) of this section, the owner or operator shall attach documentation to the certification <br />form that demonstrates the reliability and analytical soundness of the comparable formula and shall notify the Regional <br />Administrator in writing that an alternative formula was used. <br />CORRECTIVE ACTION: Complete and maintain at the facility the Substantial Harm Criteria certification form. Submit <br />proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 78 <br />Overall Inspection Comments: <br />Routine APSA Inspection <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by March 21, 2025 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of <br />having them sign. <br />FA0023343 PR0540837 SC001 02/19/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 7 of 8 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page