My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4520
>
2800 - Aboveground Petroleum Storage Program
>
PR0515710
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2025 11:16:11 AM
Creation date
4/23/2025 8:50:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0515710
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0010475
FACILITY_NAME
Saia LTL-SCA
STREET_NUMBER
4520
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17920034
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4520 S STATE ROUTE 99 STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aboveground Petroleum Storage Act Program Inspection Report <br />Date: <br />August 08, 2025 <br />Facility Address: <br />4520 S HWY 99, STOCKTONSAIA LTL - SCA <br />Facility Name: <br />Environmental Health Department <br />74 CA Health and Safety <br />Code 25270.6(a) <br />4010032 - Tank Facility Statement or Business Plan has been submitted o OUT o R o COS <br />75 CA Health and Safety <br />Code 25270.8 <br />4040001 - Spills/releases of 42 gallons or more of petroleum reported upon <br />discovery to Cal OES & UPA or 911 <br />o OUT o R o COS <br />76 CA Health and Safety <br />Code 25270.6(b) <br />4010033 - APSA program fee paid o OUT o R o COS <br />77 Code of Fed Regulations <br />112.1(b)(3), 112.2 <br />4030036 - All/any permanently closed tanks are properly closed under the <br />definition in 40 CFR 112.2 <br />o OUT o R o COS <br />78 Code of Fed Regulations <br />112.20(e) <br />4010044 - Substantial Harm Criteria certification maintained at the facility as <br />required <br />o OUT o R o COS <br />79 CA Health and Safety <br />Code 25404(e)(4) <br />4010 - Administration/Documentation - General o OUT o R o COS <br />80 4015 - Administration/Documentation - General Local Ordinance o OUT o R o COS <br />81 See below 4020 - Training - General o OUT o R o COS <br />82 4025 - Training - General Local Ordinance o OUT o R o COS <br />83 See below 4030 - Operations/Maintenance - General o OUT o R o COS <br />84 4035 - Operations/Maintenance - General Local Ordinance o OUT o R o COS <br />85 See below 4040 - Release/Leaks/Spills - General o OUT o R o COS <br />86 4045 - Release/Leaks/Spills - General Local Ordinance o OUT o R o COS <br />87 See below 4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General o OUT o R o COS <br />88 4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local <br />Ordinance <br />o OUT o R o COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item #Remarks <br />3 Code of Fed Regulations 112.3 4030038 - SPCC has been implemented <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan was not implemented, as required <br />with regard to training, inspections, recordkeeping and countermeasures for discharge discovery, response, and cleanup. <br />-The facility could not provide records of training, spill prevention briefings, monthly/annual inspections, and formal <br />external testing were during the inspection. <br />-Section 15.0 of the SPCC Plan, "Summary and Recommendations", states that emergency response procedures related <br />to conformance with CFR 112 should be posted in a conspicuous location. Posted emergency response procedures were <br />not observed during the inspection. <br />-Table 3 of the SPCC Plan states that directions for the emergency pump shut off are posted in the fueling area. <br />Directions for the emergency shut off were not observed in the fueling area during the inspection. <br />REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section must <br />prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter “SPCC Plan” or <br />“Plan”),” in accordance with § 112.7 and any other applicable section. 25270.4.5.(a): An owner or operator shall conduct <br />periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section 112.1) of <br />Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill prevention control and <br />countermeasure plan, an owner or operator shall fully comply with the latest version of the regulations contained in Part <br />112 (commencing with Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br />CORRECTIVE ACTION: Implement the SPCC plan, as required. Submit proof of correction to the EHD. <br />This is a (Class 2) Violation. <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD <br />Page 4 of 9EHD - CUPA Inspection Report IS02 8/13/2025FA0010475 PR0515710 4534664
The URL can be used to link to this page
Your browser does not support the video tag.