My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COMSTOCK
>
14290
>
2900 - Site Mitigation Program
>
PR0548283
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2026 11:14:08 AM
Creation date
6/23/2025 2:27:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0548283
PE
2960 - RWQCB LEAD AGENCY CLEAN UP SITE
FACILITY_ID
FA0027556
FACILITY_NAME
SITE DRILLING & SAMPLING SOILS
STREET_NUMBER
14290
Direction
E
STREET_NAME
COMSTOCK
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09103013
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
14290 E COMSTOCK RD LINDEN 95236
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
eurafins <br /> Air Taxics <br /> LABORATORY NARRATIVE <br /> Modified ASTM D-1946 <br /> Brusca Associates,Inc. <br /> Workorder#2308374C <br /> One 1 Liter Summa Canister sample was received on August 16, 2023. The laboratory performed <br /> analysis via Modified ASTM Method D-1946 for Oxygen in air using GC/TCD. The method involves <br /> direct injection of 1.0 mL of sample. <br /> On the analytical column employed for this analysis, Oxygen coelutes with Argon. The corresponding <br /> peak is quantitated as Oxygen. <br /> Method modifications taken to run these samples are summarized in the table below. Specific project <br /> requirements may over-ride the EATL modifications. <br /> Requirement ASTMD-1946 ATL Modifications <br /> Calibration A single point A minimum of 5-point calibration curve is performed. <br /> calibration is performed Quantitation is based on average Response Factor. <br /> using a reference <br /> standard closely <br /> matching the <br /> composition of the <br /> unknown. <br /> Reference Standard The composition of any The standards used by ATL are blended to a>/=95% <br /> reference standard must accuracy. <br /> be known to within <br /> 0.01 mol%for any <br /> component. <br /> Sample Injection Volume Components whose The sample container is connected directly to a fixed <br /> concentrations are in volume sample loop of 1.0 mL on the GC. Linear range is <br /> excess of 5 %should defined by the calibration curve.Bags are loaded by <br /> not be analyzed by vacuum. <br /> using sample volumes <br /> greater than 0.5 mL. <br /> Normalization Normalize the mole Results are not normalized. The sum of the reported <br /> percent values by values can differ from 100%by as much as 15%,either <br /> multiplying each value due to analytical variability or an unusual sample matrix. <br /> by 100 and dividing by <br /> the sum of the original <br /> values.The sum of the <br /> original values should <br /> not differ from 100% <br /> by more than 1.0%. <br /> Precision Precision requirements Duplicates should agree within 25%RPD for detections> <br /> established at each 5 X's the RL. <br /> concentration level. <br /> Receiving Notes <br /> There were no receiving discrepancies. <br /> Page 3 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.