Laserfiche WebLink
29 January 2024 AdvancedGeo <br /> Project No. 23-7523 An Employee-Owned Company <br /> Page 4 of 8 <br /> helium meter to verify that an 18 to 25% concentration of helium was introduced and <br /> maintained in the shroud. The initial pressure and time were recorded on soil-vapor <br /> sampling field logs (Appendix A). The sample canister valves were closed after reaching <br /> 2 to 6 inches' mercury (Hg). The final pressure and time were recorded. The sampling <br /> ports on the sampling canisters were then capped with brass endcaps and the canisters <br /> were placed in a dry container (room temperature). Following sample collection, organic <br /> vapor in the wells was measured using a photo-ionization detector (PID). Soil-vapor <br /> samples were labeled with sample ID, project name, date, time, and samplers' initials. <br /> The samples were logged on a chain-of-custody form and placed into dry containers. <br /> The soil-vapor samples were logged on a chain-of-custody form and delivered to Eurofins <br /> Air Toxics, LLC, (Eurofins), an ELAP-certified analytical laboratory. Soil-vapor samples <br /> were analyzed for the following chemical constituents: <br /> • VOCs in accordance with EPA Method TO-15. <br /> • Helium in accordance with ASTM D1946M. <br /> 2.3. INDOOR AIR SAMPLING PRODCEDURE <br /> On 09 January 2024, the buildings located at 306, 308A and 308B Ham Lane were <br /> monitored and inspected to locate indoor contaminant sources that could potentially bias <br /> air sampling results. Additionally, background ambient air (outdoor) was monitored in the <br /> eastern portion of the property. <br /> Indoor air contaminant sources were monitored and located using an organic vapor meter <br /> (OVM) equipped with a PID calibrated to a detection limit of parts per billion by volume <br /> (ppb; MiniRae 3000). Organic vapor measurements were recorded from the following <br /> areas of the property: <br /> • Background Outdoor Air = 0 ppb. <br /> • 306 Ham Lane = 0-2 ppb at floor cracks and ambient air. <br /> • 308A Ham Lane = 4-7 ppb at floor cracks and ambient air. <br /> • 308B Ham Lane = 28-30 ppb at floor crack and ambient air. <br /> The results of the indoor air pre-sample inspection are presented in the Indoor Air Source <br /> Screening Forms provided in Appendix B. <br /> On 09 January 2024, AGI collected a total of three (3) passive integrated air samples <br /> using laboratory supplied 6-liter Summa canisters from the above referenced indoor <br /> locations (306 Ham Lane, 308A Ham Lane and 308B Ham Lane). Additionally, a passive <br /> integrated ambient air sample was collected using a 6-liter Summa canister, outside at <br /> the eastern edge of the property building. Summa cans were positioned a minimum of <br />