%% eurofins <br /> Air Toxics <br /> LABORATORY NARRATIVE <br /> Modified TO-15 Full Scan/SIM <br /> AdvancedGeo, Inc <br /> Workorder# 2401195 <br /> Four 6 Liter Summa Canister (100% SIM Ambient) samples were received on January 10, 2024. The <br /> laboratory performed analysis via modified EPA Method TO-15 using GUMS in the Full Scan and <br /> SIM acquisition modes. The method involves concentrating up to 1.0 liters of air. The concentrated <br /> aliquot is then flash vaporized and swept through a water management system to remove water vapor. <br /> Following dehumidification, the sample passes directly into the GUMS for analysis. <br /> Method modifications taken to run these samples are summarized in the table below. Specific project <br /> requirements may over-ride the EATL modifications. <br /> Requirement TO-IS ATL Modifications <br /> ICAL%RSD acceptance criteria </=30%RSD with 2 For Full Scan: <br /> compounds allowed out 30%RSD with 4 compounds allowed out to<40%RSD <br /> to<40%RSD <br /> For SIM: <br /> Project specific;default criteria is</=30%RSD with 10% <br /> of compounds allowed out to<40%RSD <br /> Daily Calibration +-30%Difference For Full Scan: <br /> </=30%Difference with four allowed out up to</=40%.; <br /> flag and narrate outliers <br /> For SIM: <br /> Project specific;default criteria is</=30%Difference <br /> with 10%of compounds allowed out up to</=40%.;flag <br /> and narrate outliers <br /> Blank and standards Zero air Nitrogen <br /> Method Detection Limit Follow 40CFR Pt.136 The MDL met all relevant requirements in Method TO-15 <br /> App. B (statistical MDL less than the LOQ).The concentration of <br /> the spiked replicate may have exceeded 1 OX the <br /> calculated MDL in some cases <br /> Receiving Notes <br /> There were no receiving discrepancies. <br /> Analytical Notes <br /> The results for each sample in this report were acquired from two separate data files originating from <br /> the same analytical run. The two data files have the same base file name and are differentiated with a <br /> "sim" extension on the SIM data file. <br /> The recovery of surrogate 4-Bromofluorobenzene in sample IA-308A Ham was outside laboratory <br /> control limits due to high level hydrocarbon matrix interference. The surrogate recovery is flagged. <br /> Ethanol was detected at concentrations less than 5 times the reporting limit in sample Ambient. <br /> Because the preceding sample contained concentrations of Ethanol exceeding the calibration range, <br /> the result for this compound in sample Ambient may be biased high. <br /> Page 4 of 44 <br />