Laserfiche WebLink
TO E RO E K SOP No.021,REV.1 <br /> „ SOIL GAS SAMPLING METHODS <br /> ASSOCIATES,INc. <br /> PAGE 2 <br /> 1.5 REQUIREMENTS AND RESOURCES <br /> When using the Tedlar®bag collection method, the following items are needed: <br /> • A sampling port and attached sampling line, ready for sampling. <br /> • A pump (SKC universal flow pump or equivalent), capable of pumping at least 3 liters per <br /> minute (L/min)to allow purging of the sample point prior to collecting a soil gas sample. <br /> • Sampling lines (dedicated, 0.375-inch outer diameter Tygon®tubing or equivalent such as <br /> Teflon®)to connect all field equipment. <br /> • Y-branched plastic (Teflon®-lined if available) sampling hose for duplicate collection. <br /> • 500-cubic-centimeter(cc) Tedlar®bags, with metal fittings. <br /> • Vacuum chamber. <br /> • Leak check compound. <br /> When using syringes to collect soil gas, the following items are needed: <br /> • A supply of clean graduated syringes. <br /> • Plastic 3-way valve. <br /> • Aluminum foil. <br /> • Leak check compound. <br /> When using Summa canisters to collect soil gas, the following items are needed: <br /> • A supply of clean, evacuated Summa canisters with a pressure gauge to verify internal <br /> vacuum and flow controller(integrated flow controller pressure gauge may be used). <br /> • A vacuum pump (SKC universal flow pump or equivalent)to allow purging of the sample <br /> point prior to collection of soil gas samples. <br /> • Tygon®or equivalent tubing of appropriate size for connecting the sampling port to pump <br /> (during gas point purging) and the sampling port to stainless steel canister(during sample <br /> collection). <br /> • Swagelok"T" for duplicate collection. <br /> • Leak check compound. <br /> When using sorbent tubes to collect soil gas, the following items are needed: <br /> • A supply of sorbent tubes with the appropriate media. <br /> • A pump (SKC universal flow pump or equivalent), capable of pumping at least 3 L/min to <br /> allow purging of the sample point prior to collection of samples, with a low-flow adapter <br /> for sample collection(10 to 200 milliliters per minute [mL/min]), or two separate pumps. <br />