HEURESIS PCS December 2015 <br /> Determine if the XRF testing in the units or house passed or failed the test by applying the steps below. Compute <br /> the Retest Tolerance Limit by the following steps: <br /> Determine XRF results for the original and retest XRF readings. Do not correct the original <br /> or retest results for substrate bias. In single-family and multi-family housing, a result is <br /> defined as a single reading. Therefore, there will be ten original and ten retest XRF results <br /> for each house or for the two selected units. <br /> Calculate the average of the original XRF result and the retest XRF result for each testing <br /> combination. <br /> Square the average for each testing combination. <br /> Add the ten squared averages together. Call this quantity C. <br /> Multiply the number C by 0.0072. Call this quantity D. <br /> Add the number 0.032 to D. Call this quantity E. <br /> Take the square root of E. Call this quantity F. <br /> Multiply F by 1.645. The result is the Retest Tolerance Limit. <br /> Compute the average of all ten original XRF readings. <br /> Compute the average of all ten re-test XRF readings. <br /> Find the absolute difference of the two averages. <br /> If the difference is less than the Retest Tolerance Limit, the inspection has passed the retest. If <br /> the difference of the overall averages equals or exceeds the Retest Tolerance Limit, this <br /> procedure should be repeated with ten new testing combinations. If the difference of the overall <br /> averages is equal to or greater than the Retest Tolerance Limit a second time,then the inspection <br /> should be considered deficient. <br /> Use of this procedure is estimated to produce a spurious result approximately 1% of the time. That is, <br /> results of this procedure will call for further examination when no examination is warranted in <br /> approximately 1 out of 100 dwelling units tested. <br /> TESTING TIMES: <br /> In the Action Level paint test mode, the instrument takes the longest time to complete readings close to <br /> the Federal standard of 1.0 mg/cm'. The table below shows the mean and standard deviation of actual <br /> reading times by reading level for paint samples during the November 2015 archive testing. The tested <br /> instruments reported readings to one decimal place. No significant differences in reading times by <br /> substrate were observed. These times apply only to instruments with the same source strength as those <br /> tested (2.0 mCi). Instruments with stronger sources will have shorter reading times and those with <br /> weaker sources, longer reading times, than those in the table. <br /> Mean and Standard Deviation of Reading Times in Action Level Mode by Reading Level <br /> Reading (mg/cm' Mean Reading Time (seconds) Standard Deviation (seconds) <br /> < 0.7 3.48 0.47 <br /> 0.7 7.29 1.92 <br /> 0.8 13.95 1.78 <br /> 0.9— 1.2 15.25 0.66 <br /> 1.3 — 1.4 6.08 2.50 <br /> > 1.5 3.32 0.05 <br /> Page 3 of 4 <br />