Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />June 24, 2025 <br /> Facility Address: <br /> 10100 W LINNE RD, TRACY <br /> Facility Name: <br /> NORTHWEST PIPE COMPANY <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.5(b) 4010009 - 5 year review performed on SPCC and documented. <br />OBSERVATION: The facility failed to perform the 5-year review of the Spill Prevention, Control, and Countermeasure <br />(SPCC) plan. The SPCC plan was last reviewed on 4/21/2020. <br />REGULATION GUIDANCE: (b) Notwithstanding compliance with paragraph [112.5] (a) of this section, complete a <br />review and evaluation of the SPCC Plan at least once every five years from the date your facility becomes subject to <br />this part; or, if your facility was in operation on or before August 16, 2002, five years from the date your last review was <br />required under this part. As a result of this review and evaluation, you must amend your SPCC Plan within six months <br />of the review to include more effective prevention and control technology if the technology has been field -proven at the <br />time of the review and will significantly reduce the likelihood of a discharge as described in § 112.1(b) from the facility. <br />You must implement any amendment as soon as possible , but not later than six months following preparation of any <br />amendment. You must document your completion of the review and evaluation , and must sign a statement as to <br />whether you will amend the Plan, either at the beginning or end of the Plan or in a log or an appendix to the Plan. The <br />following words will suffice, “I have completed review and evaluation of the SPCC Plan for (name of facility) on (date), <br />and will (will not) amend the Plan as a result.” <br />CORRECTIVE ACTION: Immediately complete and document the 5-year review of the SPCC Plan and make any <br />necessary amendments (a Professional Engineer must certify any technical amendments). Submit verification of <br />adequate SPCC plan review completion to the EHD. <br />This is (Minor) Violation. <br /> 10 <br />Code of Fed Regulations 112.7(f)(2) 4010022 - Person has been designated as accountable for discharge prevention <br />and reports to management. <br />OBSERVATION: This facility does not have a designated person for discharge prevention. The person that was the <br />designated employee left the company seven months ago. The SPCC plan has not been updated. <br />REGULATION GUIDANCE: (f)(2) Designate a person at each applicable facility who is accountable for discharge <br />prevention and who reports to facility management. <br />CORRECTIVE ACTION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan shall designate a person at <br />the facility who is accountable for discharge prevention and who reports to facility management. Designate a person <br />accountable for discharge prevention, submit proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 31 <br />Code of Fed Regulations 112.7(f)(3) 4020002 - Spill prevention briefings are conducted annually. <br />OBSERVATION: Failure to conduct spill prevention briefing for oil-handling personnel at least once a year to assure <br />adequate understanding of the SPCC Plan, including: 1. Known discharges or failures. 2. Malfunctioning components. <br />3. Any recently developed precautionary measures. Training records were not found on site for 2022. <br />REGULATION GUIDANCE: (f)(3) Schedule and conduct discharge prevention briefings for your oil-handling personnel <br /> 32 <br />FA0004382 PR0515795 SC001 06/24/2025 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD