Laserfiche WebLink
FGL Environmental Doe ID:3D0900002_SOP_14.DOC <br /> Revision Date: 10/10/23 Page 1 of 1 <br /> Banter-Laboratory Condition Upon Receipt (Attach to COC) 2t�JC 7OL16 <br /> Sample Receipt at: CC CH STK VI <br /> 1. Number of ice chests/packages received: I Shipping tracking#(s): <br /> 2. Temp IR Guri ID #: <br /> 3. Were samples received on ice? Yes No Temps: (U.3 <br /> Surface water S WTR bast samples: A sample that has a temperature upon receipt of>10"C,whether iced or not, <br /> should be flagged unless the time since sample collection has been less than two hours. <br /> 4. Do the number of bottles received agree with the COC? No N/A <br /> 5. Were samples received intact? (i.e. no broken bottles, leaks etc.) it No <br /> 6. VOAs checked for Headspace? Yes No N <br /> 7. Were 0 analyses within holding times at time of receipt? M�P No <br /> 8. Verify sample date,time and sampler name No <br /> Sign and date the COC,place in a ziplock and p to the same ice chest as the samples. <br /> Sample Receipt Review completed by (initials) <br /> Sample Receipt at SP: <br /> 1. Number of ice chests/packages received: Shipping tracking#(s):' j <br /> v i��UCi <br /> 2. Temp IR Gun ID ff-. <br /> 3. Were samples received on ice? (Yo No Temps:/ <br /> Acceptable is above freezing to 6°C. ifritafY packages are receive <br /> d atone time check for tests/H.T.shushes! <br /> 4. Do the number of bottles received agree with the COC? Ye No N/A <br /> 5. Were samples received intact? (i.e. no broken bottles,leaks etc.) a No <br /> Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br /> Sample Verification, Labeling and Distribution: <br /> 1. Were all requested analyses understood and acceptable? No <br /> 2. Did bottle labels correspond with the client's ID's? No <br /> 3. Were all bottles requiring sample preservation properly preserved. No N/A FGL <br /> lExceptlon:Oil&Crease,VOA and CM verified In labj <br /> 9 <br /> 4. VOAs checked for. Headspace? Yes No <br /> S. Have rush or project due dates been checked and accepted? Ye No <br /> 6. Were all analyses within holding times at time of receipt? No <br /> Attach labels to the containers and include a copy of the COC for lab delivery. <br /> Sample Receipt, Login and Verification completed by (initials): <br /> (Discrepancy Documentation: <br /> Any items above which are "No"or do not meet specifications (i.e. temps) must be resdlved. <br /> 1. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: <br /> 2. Person Contacted: Phone Number: <br /> Initiated By: <br /> Problem: (3012023) 0M <br /> Resolution: Luhdorff& Scalmanini consulting _ 0• <br /> I STK2457040 e 0' <br /> (Please use the back of this sheet for additional commer iv 11/18/2024 07.12:07 --' •M <br /> I1���STK245790l011f h� <br />