2025 ANNUAL GROUNDWATER MONITORING REPORT
<br /> TEICHERT AGGREGATES AND GRANITE CONSTRUCTION VERNALIS AREA
<br /> vandalized in 2005. In 2019, Granite#3 was no longer in operation and was replaced with Granite#5 for
<br /> water quality monitoring purposes. From 1994 to 1997,the Koster irrigation well was sampled
<br /> periodically(depending on the availability of a tractor engine for the pump).
<br /> Samples from the water quality network wells are analyzed for electrical conductivity(EC),total
<br /> dissolved solids(TDS), pH,general minerals(calcium, magnesium, sodium, potassium, sulfate, chloride,
<br /> total alkalinity[including hydroxide, carbonate, and bicarbonate alkalinity], and total hardness), nitrate,
<br /> nitrite,fluoride, boron, and metals(copper, iron, manganese, and zinc). Samples from the Hall and
<br /> Faulkner domestic wells are also analyzed for coliform bacteria (SM 9221B [15-tube] procedure with
<br /> fecal confirmation). Phosphorus sampling was discontinued in 1998.
<br /> Teichert's ongoing monitoring and reporting activities are inclusive of(and exceed) activities specified in
<br /> Granite's approved Groundwater Monitoring Plan (I-SCE, 2009). Specifically, Granite's approved
<br /> Groundwater Monitoring Plan includes:
<br /> 1. Semi-annual groundwater level measurements in five shallow wells(Hall, Rustan,Thoming,
<br /> Koster,4S/6E-5A1), one composite well (Petz),and four deep wells(South Tracy#3,Granite
<br /> #4, Brown's#1, Brown's New). Faulkner is used in place of the destroyed Thoming well.
<br /> Blewitt Domestic is used in place of Koster. Data from South Tracy#1,South Tracy 9054,
<br /> Granite#3, and Granite#5 are available to supplement data for South Tracy#3 and Granite
<br /> #4.
<br /> 2. Semi-annual groundwater quality retrieval from one shallow well (Hall)and three deep wells
<br /> (South Tracy#3, Granite#3,and Brown's New). Granite#5 and/or Granite#4 are used in
<br /> place of Granite#3. Groundwater quality laboratory analyses shall consist of the same
<br /> constituents listed above for Teichert's compliance monitoring activities minus nitrite,
<br /> fluoride,total hardness, and bacteriological analyses.
<br /> 3 SAMPLING PROCEDURES
<br /> Prior to the wells'annual sampling, depth-to-water measurements are obtained in relation to the wells'
<br /> surveyed reference points, i.e.,the top of the well casings, by lowering an electrical sounder in the well
<br /> casing following the manufacturer's guidelines. Field staff double-checks readings and records
<br /> measurements to the nearest 0.01 foot. Beginning in May 2024,wells that have had entanglement
<br /> issues or blockages inside the well have had water levels measured with an acoustic sounder.All
<br /> elevations are given in reference to the National Geodetic Vertical Datum of 1929, i.e.,the mean sea
<br /> level datum (msl). It is noted on the field sheet,whether the well was pumping at arrival.
<br /> Wells are purged until indicator parameters(temperature, pH,and electrical conductivity) have
<br /> stabilized prior to sample retrieval.Stabilization is defined as consecutive readings where parameters do
<br /> not vary by more than 5 percent.Visual (color,occurrence of solids),olfactory(odor)and other
<br /> observations(e.g.,wellhead conditions,well access,ground conditions,weather)are noted as
<br /> appropriate.The following instrumentation is used by LSCE staff:
<br /> LUHDORFF&SCALMANINI
<br /> CONSULTING ENGINEERS 4
<br />
|