Laserfiche WebLink
SAN JOAQUIN AMENDED Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ONE STOP MARKET* 11151 W LOUISE AVE, MANTECA T1 December 02, 2025 <br /> 59 CA Code of Regulations 2712(b)(1-2) 2030001 - Records of release detection monitoring and maintenance properly <br /> maintained (TCR 9d) <br /> OBSERVATION: The following maintenance and monitoring records for the last three years were not found on site: <br /> -2024 overfill prevention equipment testing <br /> -2024 spill container testing <br /> -2023 monitoring system certification <br /> - 2023 spill container testing <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br /> (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings <br /> of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings <br /> and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last <br /> three years on site. <br /> This is a Repeat(Class 2)Violation. <br /> 68 CA Code of Regulations 2712(i), 2634(e) 2030046 -A current UST Response Plan has been submitted <br /> OBSERVATION: An approved copy of the response plan was not available for inspection. <br /> REGULATION GUIDANCE: A copy of this plan shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Corrected on-site. An approved copy of the response plan was printed during the inspection. <br /> This is a Repeat(Class 2)Violation. <br /> 69 CA Code of Regulations 2712(i) 2030033 -A current UST monitoring plan has been submitted and is readily accessible <br /> at the facility <br /> OBSERVATION: An approved copy of the monitoring plans was not available for inspection. <br /> REGULATION GUIDANCE: A copy of these plans shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Corrected on-site. Copy of monitoring plans were printed during the inspection. <br /> This is a Repeat(Class 2)Violation. <br /> 77 CA Code of Regulations 2712(f) 2030073- Facility has corrected cited violations within 30 days of receiving report <br /> OBSERVATION: An inspection was last done on 12/17/2024 and an inspection report was issued identifying information <br /> to be submitted to bring this site into compliance. This information was required to be submitted by 1/16/2025. This <br /> information has not been received resulting in a non-compliant status for this facility. <br /> REGULATION GUIDANCE: An operator that receives an inspection report shall have 30 days to submit a written <br /> response that includes a statement documenting corrective actions taken or proposing corrective actions which will be <br /> taken. <br /> CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is submitted <br /> within 30 days of receiving an inspection report. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS02 Page 6 of 7 FA0000819 PR0231429 4583346 12/2/2025 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />