Laserfiche WebLink
27 August 2025 AdvancedGeo <br /> Project No. 25-8011 An Employee-Owned Company <br /> Page 13 of 14 Q, X <br /> • The nitrogen loading rate is slightly above the EHD established limit of 10 ppm. <br /> • Nitrates were detected well above the State of California Maximum Contaminant <br /> Level (MCL) of 10 mg/I in the onsite water well; DBCP was not detected above the <br /> laboratory reporting limit. AGI recommends the installation and operation of <br /> appropriate water treatment equipment, such as ion exchange, distillation, or <br /> reverse osmosis, to reduce nitrate concentrations to below the MCL and provide a <br /> safe and reliable drinking water supply. <br /> • All approved septic system use should follow the EHD Onsite Wastewater <br /> Treatment System Standards. <br /> 12.0. LIMITATIONS <br /> Our professional services were performed using that degree of care and skill ordinarily <br /> exercised by environmental consultants practicing in this or similar localities. The findings <br /> were based on field testing results. Evaluations of the hydrogeologic conditions at the site <br /> for the purpose of this investigation were made from a limited number of available data <br /> points (i.e., test hole field data and water data) and subsurface conditions may vary away <br /> from these data points. No other warranty, expressed or implied, is made as to the <br /> professional interpretations, opinions and recommendations contained in this report. <br />