My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LONGE
>
7910
>
2231-2238 – Tiered Permitting Program
>
PR0536175
>
COMPLIANCE INFO_2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2026 8:16:54 PM
Creation date
12/18/2025 4:15:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2025
RECORD_ID
PR0536175
PE
2231 - HAZARDOUS WASTE PBR FACILITY
FACILITY_ID
FA0012466
FACILITY_NAME
PREMIER FINISHING
STREET_NUMBER
7910
Direction
S
STREET_NAME
LONGE
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
7910 S LONGE STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Premier Finishing PR0520875, PR0516115, PR0536175 <br /> 7910 S. Longe St. Stockon, CA 95206 <br /> 7/30/25 <br /> IMG 1760 Ball valve 8 observed in the open position in wastewater treatment area <br /> IMG 1761 Tank footings for the 750-gallon hazardous waste tank missing floor bolts <br /> IMG-1762 Liquid observed on the ground below the 750-gallon hazardous waste tank in the <br /> wastewater treatment area <br /> IMG 1763 Guidance posted in wastewater treatment area <br /> IMG 1764 Handling and disposal of waste guidance posted in wastewater treatment area <br /> IMG 1765 Waste disposal guidance posted in wastewater treatment area <br /> IMG 1767 HW tanks stem daily inspection log for July 2024—Jul 15-19 left blank <br /> IMG 1768 HW tanks stem daily inspection log for August 2024—August 27-30 left blank <br /> IMG 1769 HW tanks stem daily inspection log for October 2024 —October 14-15 left blank <br /> IMG 1771 Outdated map posted in wastewater treatment area <br /> IMG 1772 Cabinet Assembly Area <br /> IMG 1773 Forklift charging area, not labeled on HMBP ma <br /> IMG 1774 Waste disposal at the time of use <br /> IMG 1775 55-gallon drums of waste aerosol cans observed in the corner of the building, no labeling <br /> IMG 1776 Stripper tank, not currently in use <br /> IMG 1777 55-gallon drum hazardous waste label with illegible required information <br /> IMG 1778 55-gallon hazardous waste drum and large metal filter <br /> IMG 1779 Large metal waste filter <br /> IMG_1780 55-gallon drum with hazardous waste label missing physical state and hazardous <br /> properties. Accumulation date 9/17/24 <br /> IMG 1781 55-gallon hazardous waste drum observed in storage. <br /> IMG 1782 Large metal waste filters observed in outdoor storage area <br /> IMG 1783 Large metal waste filters observed in multiple areas of outdoor waste storage <br /> IMG 1784 55-gallon poly drum with hazardous waste label with 11/2/21 accumulation start date <br /> IMG-1785 Second 55-gallon poly drum with hazardous waste label with 11/2/21 accumulation start <br /> date <br /> IMG 1786 Two 55-gallon drums and large metal waste filters in outdoor waste storage area. <br /> IMG-1787 Hazardous waste container with hazardous waste label and "Empty Daily" label observed <br /> in outdoor storage area <br /> IMG 1788 Unlabeled poly drum observed in outdoor waste storage area <br /> IMG 1789 Oen drum observed in outdoor waste storage pile with paint can inside <br /> IMG 1790 Paint can observed inside open drum in waste pile <br /> IMG 1791 Additional waste pile in outdoor storage <br /> IMG 1792 Additional large metal filters observed in waste area next to "scrap metal" bin <br /> IMG 1793 Appliance waste observed in outdoor storage area <br /> IMG 1794 Additional appliance waste observed in outdoor storage area <br /> IMG 1795 55-gallon drum with hazardous waste label missing all other required information <br /> IMG-1796 55-gallon drum near loading dock with hazardous waste label missing all other required <br /> information <br /> IMG 1797 Unlabeled 55-gallon drum near loading dock <br /> IMG 1798 Back side of power washing unit, not currently in use <br /> IMG-1799 Back side of power washing unit, not currently in use, two drums with missing/incomplete <br /> labels <br /> IMG-1801 Dark material observed on back lot, facility staff stated they had recently repaved, and <br /> the material is asphalt. <br /> IMG 1802 Dark staining observed in dirt area of back lot <br /> IMG 1803 Interior of power washing unit, not currently in use <br /> IMG 1804 Interior of power washing unit containing debris, not currently in use <br /> IMG-1805 55-gallon drum of Isoprep 164 observed with staining dripping down the side and on the <br /> round underneath it <br /> IMG 1806 5-gallon bucket of Actane 73, deteriorated and staining on the ground around it <br /> Lynsey Sammons, REHS Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.