My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1744
>
2900 - Site Mitigation Program
>
PR0542458
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2026 12:59:37 PM
Creation date
1/26/2026 12:56:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0542458
PE
2960 - RWQCB LEAD AGENCY CLEAN UP SITE
FACILITY_ID
FA0024399
FACILITY_NAME
PARKWOODS CLEANERS
STREET_NUMBER
1744
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728032
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
1744 W HAMMER LN STOCKTON 95209
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GeosptecO <br /> consultants <br /> The lid of the lung box will be opened, the valve on the Tedlar bag closed, and the Tedlar bag <br /> removed from the lung box. The Tedlar bag will be connected to the helium meter,photoionization <br /> (PID), and landfill gas meter (oxygen, carbon dioxide and methane) in sequence, by opening the <br /> Tedlar bag valve, and recording the stabilized readings. <br /> If the concentration of helium in the Tedlar bag is greater than 5% of the concentration in the <br /> shroud, the probe seal and fittings should be checked to determine the location of the leak. Once <br /> the leak has been fixed, resume purging and field screening. The purging and field screening <br /> procedure will be repeated for a minimum of three sets of readings. <br /> 5 SUMMA CANISTER LEAK TEST <br /> Valves V-1 and V-2 will be closed and then valve V-3 (summa canister valve) will be opened to <br /> induce a vacuum on the sample train. Valve V-3 will then be closed to leave a vacuum of about 30 <br /> in Hg in the sample train. The vacuum in the sample train will be observed for a short duration(30 <br /> seconds) to ensure it does not dissipate as a final check that the sample train does not contain any <br /> leaks. <br /> 6 SUMMA CANISTER SAMPLING <br /> After the summa canister leak test,valve V-1 will then be opened. Then valve V-3 (summa canister <br /> valve) will be opened to begin the sample collection. The sample collection start time should be <br /> recorded. The vacuum gauge on the Summa canister should be monitored and valve V-3 should <br /> be closed when the residual vacuum in the canister is about 5 in-Hg. The sample collection finish <br /> time should be recorded. Following sample collection, connect a vacuum gauge directly above <br /> valve V-3, open valve V-3 and record the final vacuum of the summa canister. Close valve V-3 <br /> after the vacuum reading is recorded. The final vacuum reading will be included on the chain of <br /> custody so that the receiving laboratory can confirm if the summa canister has leaked during <br /> transit. <br /> 7 BLANK SAMPLES (OPTIONAL) <br /> Blank samples will be collected based on the project specific data quality objectives. <br /> An equipment blank is collected by connecting a Summa canister to a fully assembled soil gas <br /> probe(screen,tubing,and valve)prior to installation,via Swagelok fittings through a 200 milliliter <br /> per minute(mL/min) flow controller. The Summa canister valve is opened to draw the contents of <br /> the tubing and outdoor air into the canister through the probe tip and Swagelok valve. <br /> Trip blanks are required by some jurisdictions and consist of a unused Summa canister being sent <br /> by the laboratory to travel with the primary laboratory samples and then being returned to the <br /> laboratory unused. The laboratory will then proceed to analyzed the contents of the Summa <br /> canister. <br /> 2 October 2020 <br />