GeosptecO <br /> consultants <br /> The lid of the lung box will be opened, the valve on the Tedlar bag closed, and the Tedlar bag <br /> removed from the lung box. The Tedlar bag will be connected to the helium meter,photoionization <br /> (PID), and landfill gas meter (oxygen, carbon dioxide and methane) in sequence, by opening the <br /> Tedlar bag valve, and recording the stabilized readings. <br /> If the concentration of helium in the Tedlar bag is greater than 5% of the concentration in the <br /> shroud, the probe seal and fittings should be checked to determine the location of the leak. Once <br /> the leak has been fixed, resume purging and field screening. The purging and field screening <br /> procedure will be repeated for a minimum of three sets of readings. <br /> 5 SUMMA CANISTER LEAK TEST <br /> Valves V-1 and V-2 will be closed and then valve V-3 (summa canister valve) will be opened to <br /> induce a vacuum on the sample train. Valve V-3 will then be closed to leave a vacuum of about 30 <br /> in Hg in the sample train. The vacuum in the sample train will be observed for a short duration(30 <br /> seconds) to ensure it does not dissipate as a final check that the sample train does not contain any <br /> leaks. <br /> 6 SUMMA CANISTER SAMPLING <br /> After the summa canister leak test,valve V-1 will then be opened. Then valve V-3 (summa canister <br /> valve) will be opened to begin the sample collection. The sample collection start time should be <br /> recorded. The vacuum gauge on the Summa canister should be monitored and valve V-3 should <br /> be closed when the residual vacuum in the canister is about 5 in-Hg. The sample collection finish <br /> time should be recorded. Following sample collection, connect a vacuum gauge directly above <br /> valve V-3, open valve V-3 and record the final vacuum of the summa canister. Close valve V-3 <br /> after the vacuum reading is recorded. The final vacuum reading will be included on the chain of <br /> custody so that the receiving laboratory can confirm if the summa canister has leaked during <br /> transit. <br /> 7 BLANK SAMPLES (OPTIONAL) <br /> Blank samples will be collected based on the project specific data quality objectives. <br /> An equipment blank is collected by connecting a Summa canister to a fully assembled soil gas <br /> probe(screen,tubing,and valve)prior to installation,via Swagelok fittings through a 200 milliliter <br /> per minute(mL/min) flow controller. The Summa canister valve is opened to draw the contents of <br /> the tubing and outdoor air into the canister through the probe tip and Swagelok valve. <br /> Trip blanks are required by some jurisdictions and consist of a unused Summa canister being sent <br /> by the laboratory to travel with the primary laboratory samples and then being returned to the <br /> laboratory unused. The laboratory will then proceed to analyzed the contents of the Summa <br /> canister. <br /> 2 October 2020 <br />