Laserfiche WebLink
Table 1. Proposed Well Construction <br /> Monitoring Zone Screen Interval (feet bgs) Gravel Pack(feet bgs) <br /> Zone 1 1000-1010 990-1020 <br /> Zone 2 1150-1160 1140-1170 <br /> The area between ground surface and the monitoring zone will be sealed with a bentonite grout or <br /> bentonite pellets.The sealing material shall be a graded chip between% inch to 3/8 inch. An approved <br /> product for the bentonite chip seals is "HOLEPLUG", and for the bentonite grout"QUICK-GROUT" both <br /> manufactured by the NL Baroid Division of NL Industries, Inc.Technical data for these products are <br /> included in Attachment D. <br /> In the event the monitoring well must be destroyed,two proposed well destruction plans which were <br /> provided by Tylor McMillan's Well Service, LLC for TW1 are included in Attachment E. <br />