COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2026 1:48:48 PM
Creation date
3/2/2026 2:53:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231111
PE
2361 - UST FACILITY
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
14121403
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
2285 E FREMONT ST STOCKTON 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Release Detection Equipment Testing Report Form <br /> v. MONITORING SYSTEM AND PROGRAMMING <br /> A separate Release Detection Equipment Testing Report Form must be prepared for each <br /> monitoring system. <br /> Manufacturer of Monitoring Model of Monitoring Systern Software Version Installed <br /> System Control Panel Control Panel <br /> Bleeder-Root TL - 50 <br /> Attach the post-testing reporls if the monitoring system is capable of generating Yes No NA <br /> either: ❑ Monitoring System Set-up Report ❑ Alarm History Deport <br /> Is all release detection equipment that was tested operational per manufacturer's ❑ <br /> specifications? <br /> Is the secondary containment free of darnage, debris, or liquid? U <br /> Are the release detection audlbfe and visual alarms operational? ❑ <br /> Have all sensors been: 1) visually Inspected for wiring kinks, breaks and residual ❑ ❑ <br /> buildup on floats; and ) tested for functionality and confirmed operational? <br /> Are a]I sensors instalied to detect a release at the earliest opportunity? ❑ ❑ <br /> Was the monitoring system set-up reviewed, and proper settings confirmed? ❑ ❑ 1 <br /> Was the monitoring system's backup battery visually inspected. functionally tested. ❑ l❑ <br /> and confirmed operational? <br /> Was it confirmed that the flow of hazardous substance stops at the dispenser if a ❑ ❑ <br /> release is detected in the under-dispenser containment? <br /> Does the pressure supply pump automatically shut down if the piping secondary Q ❑ <br /> cortain men t monitoring system fails to operate or is disconnected? <br /> Does the pressure supply pump automatically shut down if the piping secondary <br /> containment monitoring system detects a release? Which sensors initiate positive 0 ❑ <br /> shut down? (Check all that apply) ❑ Containment Sump ❑ UDC <br /> If release detection alarms are relayed to a remote monitoring center, is all ❑ D <br /> communication equipment operational? <br /> If there is a ny buried single-wa 11 suction hazardous substance piping. was it <br /> confirmed using the inspection method approved by the Unified Program Agency, ❑ ❑ <br /> that the pipe contents drain tuck into the UST if the suction is released? <br /> Desciibe all answers marked " o" or 'Fail"and the proposed remedy in Section 8_ <br /> t_ist all equipment either replaced or repaired (including cleaning or adjustment) in Section 8. <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.