My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU-2601127
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LUCERNE
>
6185
>
2600 - Land Use Program
>
SU-2601127
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2026 4:50:36 PM
Creation date
3/3/2026 12:43:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU-2601127
PE
2664 - VARIANCE - FLOOD (VR)
STREET_NUMBER
6185
Direction
W
STREET_NAME
LUCERNE
STREET_TYPE
AVE
City
TRACY
Zip
95304
APN
21309030
CURRENT_STATUS
Closed - Issued
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
6185 W LUCERNE AVE TRACY 95304
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL FOUNDATIONS SPECIAL INSPECTIONS <br /> 1. ALL DIMENSIONS ARE TO BE FIELD VERIFIED BY THE CONTRACTOR PRIOR FOUNDATION WORK TO BE DONE PER 2022 CBC CHAPTER 18. THIRD—PARTY SPECIAL INSPECTIONS SHALL BE REQUIRED FOR THE FOLLOWING <br /> TO COMMENCING WORK OR FABRICATION. IF ANY CONDITION EXISTS NOT PER 2022 CBC CHAPTER 17: <br /> AS SHOWN ON THE DRAWINGS THE ENGINEER SHALL BE NOTIFIED FOUNDATION DESIGN FOR THIS PROJECT IS BASED ON: <br /> IMMEDIATELY. —ASSUMED BEARING CAPACITY OF 1500 PSF PER CBC TABLE 1806.2 [ ] CO RETE <br /> 2. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE —ASSUMED EXPANSION INDEX OF LESS THAN 20 [ EXCEPTION — NOT NEEDED — 2500 PSI CONCRETE <br /> OVER SCALED DRAWINGS. VERIFY DIMENSIONS AND MEASUREMENTS AT SITE. —ASSUMED SOIL SITE CLASS D [ V J EXCEPTION — NOT NEEDED — NON—STRUCTURAL SLAB <br /> 3. THE CONTRACTOR WILL HOLD HARMLESS, INDEMNIFY AND DEFEND THE —ASSUMED PASSIVE RESISTANCE OF 100 PCF <br /> OWNER, THE ENGINEER, HIS CONSULTANTS, AND EACH OF THEIR OFFICERS, —ASSUMED SOIL FRICTION COEFFICIENT OF 0.25 [ POST—INSTALLED ANCHOR BOLTS IN CONCRETE <br /> EMPLOYEES AND AGENTS, FROM ANY AND ALL LIABILITY CLAIMS, LOSSES OR —WATER TABLE ASSUMED TO BE WELL BELOW THE FOUNDATION <br /> DAMAGE ARISING OR ALLEGED TO ARISE FROM THE PERFORMANCE OF THE [ ] STRUCTURAL MASONRY <br /> WORK DESCRIBED HEREIN, BUT NOT INCLUDING THE SOLE NEGLIGENCE OF THE IF THE SOIL CONDITIONS ARE NOT EQUAL TO OR BETTER THAN THE <br /> OWNER, ENGINEER, HIS CONSULTANTS, AND EACH OF THEIR OFFICERS, ASSUMPTIONS ABOVE, THE CURRENT DESIGN WILL BE VOID AND THE OWNER <br /> EMPLOYEES AND AGENTS. AND/OR CONTRACTOR SHALL CONSULT THE LOCAL BUILDING DEPARTMENT [ ] CAISSON — CONTINUOUS INSPECTION <br /> 4. ALL WORK SHALL BE PERFORMED BY LICENSED CONTRACTOR(S) USING WHETHER A GEOTECHNICAL INVESTIGATION SHALL BE PERFORMED. DEEP FOUNDATIONS <br /> MATERIALS AND METHODS IN ACCORDANCE WITH APPLICABLE SECTIONS OF [ ] <br /> THE INTERNATIONAL BUILDING CODE (IBC) 2021 EDITION, 2022 CALIFORNIA IF A GEOTECHNICAL INVESTIGATION IS NEEDED, THE ENGINEER OF RECORD <br /> BUILDING CODE (CBC), LOCAL CODES AND ORDINANCES. REPORT ALL SHALL BE NOTIFIED IMMEDIATELY. [ ] STRUCTURAL STEEL <br /> DISCREPANCIES TO THE DESIGNER IMMEDIATELY. [ ] WOOD — HIGH—LOAD DIAPHRAGM 0 SCALE BAR <br /> 5. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, 1" <br /> THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR 01 25mm <br /> THE CONDITIONS AT THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS [ ] PRESTRESSED STEEL TENDONS IF THIS BAR IS NOT <br /> AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT AS SHOWN, ADJUST <br /> WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING [ V J STRUCTURAL FIELD WELDING, IF USED SCALES ACCORDINGLY <br /> HOURS. <br /> 6. ANY CHANGES TO THE APPROVED SET OF PLANS WITHOUT NOTIFYING THE [ V/J HIGH—STRENGTH BOLTING, IF USED 2025 COPYRIGHT BY <br /> ENGINEER PRIOR TO SUCH CHANGES ABSOLVES SAID ENGINEER FROM ANY JTOSTE ENGINEERING <br /> AND ALL RESPONSIBILITY WITH RESPECT TO THE LIABILITY, DAMAGE OR THIS DRAWING AND/OR <br /> EXTRA WORK RESULTING FROM SAID CHANGES. DOCUMENT SHALL NOT BE <br /> ALTERED, REPRODUCED, <br /> STRUCTURAL STEEL CHANGED, TRANSFERRED, <br /> GRADING WR cTENoPIECo SET FROM <br /> SEE STEEL BUILDING PLANS. <br /> JTOSTE ENGINEERING. <br /> 1. IF EXPANSIVE CLAY SOIL CONDITIONS EXIST, THE CONTRACTOR MUST UNAUTHORIZED USE OF <br /> CONSULT WITH A SOILS ENGINEER FOR SUBGRADE REQUIREMENTS AND THIS DRAWING AND/OR <br /> COORDINATE EARTHMOVING OPERATIONS TO ENSURE THAT APPROVED DOCUMENT BY A THIRD <br /> SUBGRADE MATERIALS ARE RESERVED IN SUFFICIENT QUANTITIES TO DRAINAGE PARTY WILL HOLD JTOSTE <br /> ACCOMMODATE CONCRETE FOOTINGS AND SLABS. ENGINEERING HARMLESS. <br /> 2. ALL CONCRETE FOOTINGS AND SLABS SHALL BEAR UPON AND/OR ALL STORMWATER TO BE RETAINED ON SITE AND DRAINED TO THE EXISTING <br /> PENETRATE INTO UNDISTURBED SOIL OR COMPACTED SOIL: EACH SOIL SHALL OPEN GROUND. <br /> HAVE A MINIMUM IN—PLACE DENSITY OF 90% OF MAXIMUM DENSITY AT <br /> OPTIMUM MOISTURE CONTENT AT THE PROJECT SITE. <br /> 3. PROVISIONS SHALL BE MADE FOR THE CONTROL AND DRAINAGE OF <br /> SURFACE WATER AROUND BUILDINGS. THE GROUND IMMEDIATELY ADJACENT TO <br /> THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING AT A SLOPE <br /> OF 2% TO 5% FOR A MINIMUM DISTANCE OF TEN FEET MEASURED Knowwhays below. <br /> PERPENDICULAR TO THE FACE OF THE WALL OR AN APPROVED ALTERNATE Call before you dig. <br /> METHOD OF DIVERTING WATER AWAY FROM THE FOUNDATION SHALL BE USED. <br /> THE PROCEDURE USED TO ESTABLISH THE FINAL GROUND LEVEL ADJACENT TO <br /> THE FOUNDATION SHALL ACCOUNT FOR ADDITIONAL SETTLEMENT OF THE <br /> BACKFILL. <br /> 4. EXCAVATION AND GRADING TO BE DONE PER 2022 CBC, APPENDIX <br /> CHAPTER J. <br /> H <br /> cf) <br /> W <br /> c/) Z <br /> LU <br /> PLUMBING w O <br /> NO PLUMBING PROPOSED FOR THIS PROJECT. z > rn o0 <br /> w < Ln �a Uc) <br /> U � pi�i I � N <br /> LiJQxzQ .q- p <br /> 0 Ujj U (0 � O <br /> xCDQU � I � .'d- <br /> � QU � U �p <br /> � J Q O <br /> CD 00 a <br /> LD <br /> REINFORCING STEEL L9 N <br /> SEE STEEL BUILDING PLANS. w Z PO 0000 <br /> Uj <br /> U LO <br /> LqWCD <br /> W WN <br /> CONCRETE w <br /> W <br /> SEE STEEL BUILDING PLANS. Z U M <br /> w O <br /> 0 U <br /> k9 O C3 <br /> 01F Z W Z <br /> W <br /> � W <br /> LW <br /> O O <br /> A w <br /> II � <br /> . � <br /> Z <br /> Ma <br /> �o0,0F E SS/oAl <br /> �P�,BERTOT Fyn, <br /> W o 01 <br /> No. 77,3 <br /> j r <br /> i <br /> ELECTRICAL f. . �qT� of I \ca <br /> NO ELECTRICAL PROPOSED FOR THIS PROJECT. <br /> SIGNED: 6-29-2025 <br /> SHEET <br /> 2 <br /> 2 OF 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.