My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAZELTON
>
1810
>
2300 - Underground Storage Tank Program
>
PR0231141
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2026 2:02:15 PM
Creation date
3/9/2026 9:46:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231141
PE
2361 - UST FACILITY
FACILITY_ID
FA0003954
FACILITY_NAME
SJ CO PUBLIC WORKS CORP YARD*
STREET_NUMBER
1810
Direction
E
STREET_NAME
HAZELTON
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15518002
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1810 E HAZELTON AVE STOCKTON 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Spill Containment Testing Report Form <br /> 6. SPILL CONTAINMENT DETAILS <br /> Test Method Developed by ❑ Manufacturer p Industry Standard ❑ Professional Engineer <br /> Test Type ❑ Pressure ❑ Vacuum 0 Hydrostatic <br /> ❑ Check this box if Appendix 6.1 continuation page is attached. <br /> Tank ID 87 OCTANE DIESEL <br /> Spill Containment Manufacturer: O P W O P W <br /> Method of Cathodic Protection p Nonmetallic ❑ Nonmetallic ❑ Nonmetallic p Nonmetallic <br /> ❑ Other ❑ Other ❑ Other ❑ Other <br /> Is the spill containment p Yes ❑ Yes ❑ Yes 0 Yes <br /> minimum capacity five gallons <br /> excluding riser volume? El No* El No* El No* El No* <br /> Method to keep spill ❑✓ Drain ❑ Drain ❑ Drain ❑✓ Drain <br /> containment empty ❑ Pump ❑ Pump ❑ Pump ❑ Pump <br /> ❑ Other ❑ Other ❑ Other ❑ Other <br /> Spill Containment Test Results p Pass ❑ Pass ❑ Pass p Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> Tank ID <br /> Spill Containment Manufacturer: <br /> Method of Cathodic Protection ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic ❑ Nonmetallic <br /> ❑ Other ❑ Other ❑ Other ❑Other <br /> Is the spill containment ❑ Yes ❑ Yes ❑ Yes ❑ Yes <br /> minimum capacity five gallons <br /> excluding riser volume? El No* El No* El No* El No* <br /> Method to keep spill ❑ Drain ❑ Drain ❑ Drain ❑ Drain <br /> containment empty ❑ Pump ❑ Pump ❑ Pump ❑ Pump <br /> ❑ Other ❑ Other ❑ Other ❑ Other <br /> Spill Containment Test Results ❑ Pass ❑ Pass ❑ Pass ❑ Pass <br /> ❑ Fail ❑ Fail ❑ Fail ❑ Fail <br /> 7. COMMENTS <br /> * ❑ Check this box if any spill containment has less than 5 gallons capacity and requires <br /> replacement. <br /> Describe all answers marked "Other," "No,"or "Fail"and each proposed remedy in Section 7. <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.