My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAZELTON
>
1810
>
2300 - Underground Storage Tank Program
>
PR0231141
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2026 2:02:15 PM
Creation date
3/9/2026 9:46:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231141
PE
2361 - UST FACILITY
FACILITY_ID
FA0003954
FACILITY_NAME
SJ CO PUBLIC WORKS CORP YARD*
STREET_NUMBER
1810
Direction
E
STREET_NAME
HAZELTON
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15518002
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1810 E HAZELTON AVE STOCKTON 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN aOAQUIN Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SJ CO PUBLIC WORKS CORP YARD* 11810 E HAZELTON AVE STOCKTON March 2 2026 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 4 23 CCR 16 2613(a)(4) and (b), 2650(a), (c), and (e) 2011012 - Facility has submitted and maintains a monitoring site <br /> plan <br /> OBSERVATION: Owner/Operator failed to submit and maintain a monitoring site plan for approval by the UPA. <br /> - Monitoring site plan is not scaled <br /> - Monitoring site plan shows that the annular for the Diesel tank is the 303, this is incorrect it is a 302. <br /> REGULATION GUIDANCE: Monitoring Site Plan —Owners or operators must submit a monitoring site plan for approval <br /> by the Unified Program Agency. The monitoring site plan must include, but is not limited to, the following:(1)A scaled <br /> diagram indicating the layout of the tank(s) and piping to the extent known, including containment sumps; (2) Locations of <br /> all release detection equipment; and (3) If applicable, each vacuum, pressure, or hydrostatic interstitial monitoring zone. <br /> CORRECTIVE ACTION: Submit and maintain a monitoring site plan. <br /> This is a Repeat (Class 2)Violation. <br /> 5 23 CCR 16 2613(a)(6) and (b), 2650(a), (d), and (e) 2011013 - Facility has submitted a complete and accurate UST <br /> Response Plan <br /> OBSERVATION: An approved copy of the response plan was not available for inspection <br /> -The emergency contact information of the Responsible person Diane Province, has not been provided. <br /> REGULATION GUIDANCE: Owners or operators must submit a response plan to the Unified Program Agency which <br /> demonstrates, to the satisfaction of the Unified Program Agency, that any unauthorized release will be removed from the <br /> secondary containment as soon as practical. This must be within a time consistent with the ability of the secondary <br /> containment to contain the hazardous substance but must not exceed 30 days. The response plan must include, but is <br /> not limited to, the following:(1)A description of the proposed methods and equipment to be used for removing and <br /> properly disposing of any hazardous substances, including the location and availability of the required equipment if not <br /> permanently on site, and an equipment maintenance schedule for the equipment located on site.(2) For methods of <br /> monitoring where the presence of the hazardous substance in the interstitial space cannot be determined directly, for <br /> example, where liquid level measurements are used as the basis for determination, the response plan must specify the <br /> proposed method(s)for determining the presence or absence of the hazardous substance if the indirect method indicates <br /> a possible unauthorized release of hazardous substance.(3)The name(s), title(s)and emergency contact information of <br /> the person(s) responsible for authorizing any work necessary under the response plan or, if applicable, identify that there <br /> is a continuously staffed emergency operations center authorized to coordinate such a response and provide a 24-hour <br /> phone number for that center. <br /> CORRECTIVE ACTION: Submit a complete and accurate UST Response Plan. <br /> This is a Repeat (Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 4 of 5 FA0003954 PR0231141 4618141 3/2/2026 <br /> CP26-U aST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.