Laserfiche WebLink
FGL Environmental Doc ID: 3DO900002_SOP_14.doc <br /> Revision Date: 10/10/23 Page 1 of 1 <br /> Inter-Laboratory Conditi0 Upon Receipt (Attach to COC) <br /> Sample Receipt at: CC CH S K VI <br /> 1. Number of ice chests/packages received: Shipping tracking#(s): a <br /> 2. Temp IR Gun ID#:TH319 <br /> 3. Were samples received on ice? Yes No Temps:Js I I I I <br /> Surface water SWTR bact samples:A sample that has a temperature upon receipt of >10°C,whether iced or not, <br /> should be flagged unless the time since sample collection has been less than two hours. <br /> 4. Do the number of bottles received agree with the COC? 6n No N/A <br /> 5. Were samples received intact? (i.e. no broken bottles, leaks etc.) =YesNo <br /> 6. VOAs checked for Headspace? Y s No NIA <br /> 7. Were all analyses within holding times at time of receipt? Y No <br /> 8. Verify sample date,time and sampler name Yes No <br /> Sign and date the COC,place in a ziplock and put in th�i s e ice chest as the samples. <br /> Sample Receipt Review completed by (initials): <br /> Sample Receipt at SP: c t Z�� <br /> 1. Number of ice chests/packa s received: Shipping tracking#(s): li g 1 <br /> �6 s qjo <br /> 2. Temp IR Gun ID#. �/t <br /> Were samples received on ice. Ye No Temps: Ix- <br /> 3. <br /> Acceptable is above freezing to 6°C. If many packages are received at one time check for tests/H.T.'s/rushes/ <br /> 4. Do the number of bottles received agree with the COC? No N/A <br /> 5. Were samples received intact? (i.e. no broken bottles, leaks etc.) No <br /> Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br /> Sample Verification, Labeling and Distribution: <br /> 1. Were all requested analyses understood and acceptable? No <br /> 2. Did bottle labels correspond with the client's ID's? No <br /> 3. Were all bottles requiring sample preservation properly preserved? es No N/A FGL <br /> (Exception:Oil&Grease,VOA and CrVI verified in labl <br /> 4. VOAs checked for Headspace? Yes No / <br /> 5. Have rush or project due dates been checked and accepted? Yes No N/A <br /> 6. Were all analyses within holding times at time of receipt? Yes No <br /> Attach labels to the containers and include a copy of the COC for lab delivery.' <br /> Sample Receipt, Login and Verification completed by (initials): <br /> Discrepancy Documentation: <br /> Any items above which are "No" or do not meet specifications (i.e. temps) must be resolved. <br /> 1. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: <br /> 2. Person Contacted: Phone Number: <br /> Initiated By: <br /> Problem: (3017919) <br /> Resolution: San Joaquin CountyEHD <br /> (Please use the back of this sheet for additional comments or co <br /> cda 03/1STU"'633435 <br /> 08:O <br /> [II[[I{Illlll({ll{ll�l{I[Ifl[li{Illll{ <br /> 9TK2r3:I435 <br />