My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/29/2026 9:35:42 PM
Creation date
4/3/2026 12:25:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231083
PE
2361 - UST FACILITY
FACILITY_ID
FA0003735
FACILITY_NAME
Top Gas Corporation
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2057 S EL DORADO ST STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Release Detection Equipment Testing Report Form <br /> 7. LINE LEAK DETECTOR TEST RESULTS <br /> ❑Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br /> ❑ Check this box if Appendix 5.2 continuation page is attached. <br /> Simulated release rate verified: (Check all that apply.) Yes No NA <br /> 0 3 GPH ❑0.1 GPH (Required only if LLD performs line tightness testing) <br /> Has the testing equipment been properly calibrated? 0 ❑ ❑ <br /> For emergency tank systems, does the LLD create an audible and visual alarm ❑ ❑ 0 <br /> when a release is detected? <br /> For mechanical LLDs, does the LLD restrict the flow through the pipe when a 0 ❑ ❑ <br /> release is detected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off when ❑ ❑ 0 <br /> a release is detected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off if the ❑ ❑ 0 <br /> monitoring system or LLD is disabled or disconnected? <br /> For electronic LLDs, does the pressure supply pump automatically shut off if the ❑ ❑ 0 <br /> monitoring system or LLD malfunctions or fails a tightness test? <br /> For electronic LLDs, have all accessible wiring connections been visually El ❑ 0 <br /> ins ected for kinks and breaks? <br /> Were all items on the equipment manufacturer's maintenance checklist 0 ❑ ❑ <br /> completed? <br /> Were all LLDs confirmed operational within regulatory requirements? 0 ❑ ❑ <br /> List only line leak detectors tested. <br /> LLD ID LLD Model Lines Monitored Pass Fail <br /> 87 MLD / F E PETRO 87 PRODUCT LINE 1 0 ❑ <br /> 91 VMI / 99 LD 2000 91 PRODUCT LINE 0 ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> ❑ ❑ <br /> Describe all answers marked "No"or "Fail"and the proposed remedy in Section 8. <br /> List all equipment either replaced or repaired (including cleaning or adjustment) in Section 8. <br /> Page 4of6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.