2602 - SOIL SUITABILITY AND NITRATE LOADING STUDY REVIEW
STREET_NUMBER
262
Direction
N
STREET_NAME
HEWITT
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09303047
CURRENT_STATUS
In Review
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
262 N HEWITT RD LINDEN 95236
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Shallow Tests <br /> TEST HOLE PERCOLATION RATE <br /> 1 (Parcel 1) 41.6 Min/In <br /> 2 (Parcel 2) 3+.gTMin/In <br /> 3 (Parcel 3) 50 Min/In <br /> 4 (Parcel 4) 27.7 Min/In <br /> *See Results in Appendix. <br /> 6.7 Discussion of any protentional problems predicted and/or the need for an engineered or <br /> alternative septic system. In this area, the soils are classified as Redding Gravelly Loam and <br /> San Joaquin Sandy Loam. Due to this classification, percolation rate, and depth to ground water, <br /> a standard septic system similar to those found on the surrounding parcels would be recommended. <br /> 6.8 Discussion of percolation rates in relation to the type, size and location of future leach <br /> fields needed at the site. Based on the results of the percolation rates and the soils profiles, it is <br /> Dillon& Murphy's opinion that the subject parcels are suited for a typical on-site sewage disposal <br /> system. These systems should be properly designed and installed according to the current San <br /> Joaquin County criteria for standard septic systems. <br /> Based on the depth to groundwater in the area, and the size of the proposed parcel,it is our opinion <br /> on that the installation of any new proposed septic system, if property installed, should not <br /> adversely affect the quality of groundwater in the area. <br /> 7.0 CONCLUSION SECTION <br /> The conclusions of this report are based on the information provided regarding the proposed <br /> development, the use of the subject property, and the site conditions as they existed at the time we <br /> excavated our test hole and performed the percolation test. It was assumed that the test hole and <br /> percolation test results are representative of the subsurface conditions in the general area. <br /> Our services were performed, our findings obtained, and our conclusions proposed in accordance <br /> with generally accepted engineering principles and practices. The warranty is in lieu of all other <br /> warranties either expressed or implied. Test findings and statements of professional opinion do <br /> not constitute a guarantee or warranty, expressed or implied. <br /> Q,�,OFESS/ON <br /> o M U Rph,` <br /> C <br /> mV-� 41U, <br /> o. 5277 <br /> *\ Exe )oL � * e Murphy <br /> sT�C II V 1�- ��`P C.E. 45277 <br /> 9�OF CA��FO <br /> 4 <br />