My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HUNTER
>
642
>
2300 - Underground Storage Tank Program
>
PR0231148
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2026 3:36:55 PM
Creation date
7/1/2026 1:38:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231148
PE
2361 - UST FACILITY
FACILITY_ID
FA0000799
FACILITY_NAME
PARK ST PETROLEUM INC
STREET_NUMBER
642
Direction
N
STREET_NAME
HUNTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13906035
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
642 N HUNTER ST STOCKTON 95202
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN AMENDED Environmental Health Department <br /> COUNTY— <br /> Greatness grows here. <br /> CP26 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PARK ST PETROLEUM INC 1642 N HUNTER ST, STOCKTON May 18, 2026 <br /> 40 23 CCR 16 2613(e) 2011002 - Installation, repair, lining, integrity, calibration, and release records maintained for life of <br /> UST <br /> OBSERVATION: Records of installation, repairs, linings, integrity certification, tank calibration charts, and/or <br /> unauthorized release reports were not kept onsite, or offsite if approved by the UPA, for the life of the UST. The following <br /> records were not observed on-site during inspection: <br /> - Installation test results <br /> - Manufacturer checklists and manuals <br /> -As-built drawings <br /> REGULATION GUIDANCE: The following records must be maintained by the owner or operator on site, or off site at a <br /> readily accessible location if approved by the Unified Program Agency, for the life of the underground storage tank <br /> system: (1) Installation records including, but not limited to: (A)Installation test results; (B)Manufacturer checklists and <br /> manuals; and (C)As-built drawings. (2) Records of repairs, including inspection reports and structural integrity <br /> certifications associated with interior lining; (3)Tank calibration charts; and (4) Unauthorized release reports. <br /> CORRECTIVE ACTION: Immediately locate and maintain these records onsite and submit copies to the UPA within 30 <br /> days. <br /> This is a (Minor)Violation. <br /> 44 23 CCR 16 2643(c) and (d); HSC 6.7 25288 2031031 - Facility has corrected all previously cited violations <br /> OBSERVATION: An inspection was last done on 05/27/2025 and an inspection report was issued identifying information <br /> to be submitted to bring this site into compliance. This information was required to be submitted by 06/26/2025. This <br /> information was received on 03/24/2026, 271 days late. <br /> REGULATION GUIDANCE: Within 60 days after receiving a compliance report or special inspection report prepared in <br /> accordance with subdivision (b) or(c), respectively, the permitholder shall file with the local agency a plan to implement <br /> all recommendations contained in the compliance report or shall demonstrate, to the satisfaction of the local agency, why <br /> these recommendations should not be implemented. Any corrective action conducted pursuant to the recommendations <br /> in the report shall be taken pursuant to Sections 25296.10 and 25299.36. <br /> CORRECTIVE ACTION: Correct all violations cited on the inspection report provided by the UPA or special inspector <br /> within 30 days for minor violations and 60 days for class II violations. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 5 of 6 FA0000799 PR0231148 4649885 5/18/2026 <br /> a <br /> CP26-UST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.