Laserfiche WebLink
Universal Biotube® Pump VaUltS (continued) <br />2" min. <br />Side view cutaway <br />Specifications <br />Top view <br />Dimensions <br />A 3 in. (76 mm) <br />B 4 in. (102 mm) <br />C 17.3 in. (439 mm) <br />D 16.6 in. (422 mm) <br />E 12 in. (305 mm) <br />Model <br />PVU57-1819 <br />PVU68-2419 <br />PVU84-2419 <br />PVU95-3625 <br />Vault height (F) <br />57 in. (1448 mm) <br />68 in. (1727 mm) <br />84 in. (1727 mm) <br />95 in. (2413 mm) <br />Lowest float setting point (G) <br />29 in. 11737 mm) <br />35 in. (889 mm) <br />51 in. (1295 mm) <br />50 in. (1270 mm) <br />Inlet hole height (H)* <br />19 in. (483 mm) <br />19 in. (483 mm) <br />19 in. (482 mm) <br />25 in. (635 mm) <br />Biotube® cartridge height (J) <br />18 in. (457 mm) <br />24 in. (510 mm) <br />24 in. (610 mm) <br />36 in. (914 mm) <br />Biotube mesh opening** <br />A in. (3 mm) <br />%a in. (3 mm) <br />% in. (3 mm) <br />% in. (3mm) <br />Filter flow area <br />4.4 ft' (0.4 m') <br />5.9 ft' (0.5 m') <br />5.9 ft2 (0.5 m2) <br />9.0 ft' 110.64 m') <br />Filter surface area <br />14.5 ft' 0.35 m') <br />19.7 ft2 (1.83 m2) <br />19.7 ft' (1.83 m') <br />30 ft' (2.79m') <br />Maximum flow rate <br />140 gpm (8.8 Usec) <br />140 gpm (8.8 Usec) <br />140 gpm (8.8 LJsec) <br />140 gpm (8.8 LJsec) <br />* May vary depending on the configuration of the tank. <br />** Vi6-in. (1.6 mm) Biotubem mesh opening available on request <br />® 2010 Orenco Systemsm Inc. MM PVLI-1 <br />Rev. 14 C 5110 <br />Page 2 of 2 <br />