My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0037786
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
20018
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0037786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/1/2018 8:38:20 AM
Creation date
7/24/2018 11:21:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0037786
PE
4371
STREET_NUMBER
20018
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95391-
APN
20907001
ENTERED_DATE
1/10/2018 12:00:00 AM
SITE_LOCATION
20018 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
DAfonskaia
标签
EHD - Public
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />1 <br />C <br />I <br />0 <br />1 <br />2 1 21 <br />DIRECT BURIAL COATING SELECTIONS <br />LISTED IN ORDER OF PREFERENCE <br />MAIN LINE COATING FBE (E-35.4) <br />MINOR REPAIRS LIQUID EPDXY (E-35.3) OR FBE PATCH STICK (E-35.4) <br />TIE-IN WELDS LIQUID EPDXY (E-35,1) <br />GIRTH WELDS LIQUID EPDXY (E-35,1) <br />BUTT WELDED FITTINGS LIQUID EPDXY (E-35.1) <br />VALVE ASSEMBLIES LIQUID EPDXY (E-35.7), WAX TAPE (E-35.7) <br />SHORT SEGMENTS OF PIPE LIQUID EPDXY (E-35.1) <br />AIR -TO -SOIL TRANSITIONS LIQUID EPDXY/PSX 700 (E-35.8) <br />PRESSURE CONTROL FITTINGS LIQUID EPDXY (E-35.7), WAX TAPE (E-35.7) <br />TIE-INS/COATING TRANSITIONS1 LIQUID EPDXY (E-35.3) <br />BORED COATING SELECTIONS <br />LISTED IN ORDER OF PREFERENCE <br />MAIN LINE COATING ARO APPLIED OVER BE (E-35,4) <br />MINOR REPAIRS LIQUID EPDXIES (E-35.2) <br />TIE-IN WELDS LIQUID EPDXIES (E-35.2) <br />NOTES: <br />11 COIJTACT THE PIPELINE ENGINEER (PLE) TO REQUEST A VARIANCE FROM THE ABOVE COATING SELECTIONS. <br />2 THE REFERENCED E-35 SERIES DOCUMENTS CONTAIN THE APPROVED PRODUCTS FOR EACH APPLICATION. <br />3 ALL COATINGS ARE TO BE APPLIED IN ACCORDANCE WITH GDS E-35 AND THE E-35 SERIES DOCUMENTS REFERENCED <br />4 FOR ALL ABOVE GROUND PIPE COATINGS, SEE GDS E-30. <br />INTERNAL CORROSION (IC) <br />DESIGN & CONSTRUCTION REVIEW <br />IC THREAT <br />YES <br />NO <br />(PER TD -4810P-16) <br />LWALLTYPE <br />(P) <br />IC REVIEW COMPLETED BY <br />LAN ID <br />DATE <br />(CORROSION ENGINEER OR DESIGNATE) <br />— GS — <br />GAS SERVICE LINE (EXISTING) <br />CORROSION ENGINEERING HAS REVIEWED <br />BARRIER <br />- - GT - - <br />THIS DESIGN AND INCORPORATED ANY <br />rte. <br />TEMPORARY BARRIER (TYPE K) <br />NECESSARY IC DESIGN AND CONSTRUCTION <br />GAS DISTRIBUTION LINE (RETIRED) <br />Diameter <br />CONSIDERATIONS. DOCUMENTATION OF <br />- - GS - - - <br />GAS SERVICE LINE (RETIRED) <br />THE REVIEW AND ACTIONS TAKEN ARE IN <br />TOE OF SLOPE <br />OWNER <br />THE JOB PACKAGE AND INCORPORATED IN <br />- - <br />TOP OF SLOPE <br />THIS DESIGN. <br />FOREIGN GAS LINE <br />f- EP <br />EDRS ROUTING NUMBER: <br />J; - <br />INSTALLATION TESTED OR INSPECTED AND <br />NOTED ON DRAWING. <br />ALL CORROSION LEVELS SATISFACTORY PER <br />PG&E GAS UTILITY STANDARD TD -41815. <br />QUALIFIED EMPLOYEE DATE <br />CORROSION MECHANIC'S SIGNATURE IS <br />REQUIRED WHEN A CPA BOUNDARY IS <br />WITHIN THE SCOPE OF THE PROJECT. <br />GT — <br />GAS TRANSMISSION LINE (PROPOSED) <br />%— <br />FENCE <br />—GT— <br />GAS TRANSMISSION LINE (EXISTING) <br />LWALLTYPE <br />(P) <br />—GD— <br />GAS DISTRIBUTION LINE (EXISTING) <br />-,'— <br />WALL <br />— GS — <br />GAS SERVICE LINE (EXISTING) <br />— — <br />BARRIER <br />- - GT - - <br />GAS TRANSMISSION LAVE (RETIRED) <br />rte. <br />TEMPORARY BARRIER (TYPE K) <br />- - GD - - • <br />GAS DISTRIBUTION LINE (RETIRED) <br />Diameter <br />GUARD RAIL <br />- - GS - - - <br />GAS SERVICE LINE (RETIRED) <br />— _-- <br />TOE OF SLOPE <br />OWNER <br />DPV <br />- - <br />TOP OF SLOPE <br />........ - <br />FOREIGN GAS LINE <br />f- EP <br />AVE <br />J; - <br />JOINTTRENCH <br />District Regulator <br />EDGE OF PAVEMENT <br />Abrasion Resistant Coating <br />DSAW <br />j FC <br />ASME <br />ET <br />ELECTRIC TRANSMISSION LINE <br />Deep Well Anode <br />FACE OF CURB <br />EJB' ----- <br />ELECTRIC DISTRIBUTION LINE <br />LBW <br />BBCL <br />Bell Bell Chill Ring <br />E <br />East <br />BACK OF WALY. <br />�. ELS — <br />ELECTRIC SERVICE LINE <br />Easement <br />BD <br />Blowdown <br />EC <br />End Curve <br />DASHED PAVEMENT MARKINGS <br />---Q `~ H ---- <br />ELECTRIC TRANSMISSION OVERHEAD <br />Electric <br />BKF <br />Backfill <br />ELEV <br />- - ---- <br />UNPAVED ROAD <br />EDz6Ff--" <br />ELECTRIC DISTRIBUTION OVERHEAD <br />Electronic Marker <br />BLVD <br />Boulevard <br />EMS <br />?al"1 �*q <br />RAILROAD <br />-- T - -- <br />TELEPHONE LINE <br />Engineer <br />BMP <br />---C — <br />FIBER OPTIC LINE <br />Edge of Pavement <br />BOM <br />--- <br />CABLE TV LINE <br />Equation <br />BR <br />— SD - <br />STORM DRAIN LINE <br />Electric Resistance Welded <br />ACCESS ROAD <br />— SS -- <br />SEWER LINE <br />Environmentally Sensitive Area <br />BV <br />Ball Valve <br />ETS <br />Electrolysis Test Station <br />LAYDOWN /STAGING / <br />y— <br />WATER LINE <br />Edge of Traveled Way <br />CONSTRUCTION IMPACT AREA <br />UNI, <br />UNKNOWN UTILITIES <br />CCV <br />EXCAVATION / BELL HOLE <br />C = _ ZI <br />CASING <br />Cl <br />Cast Iron <br />------------ <br />PROPERTY BOUNDARY <br />( l <br />J <br />SAFETY ZONE LIMITS <br />— — — - <br />PG&E EASEMENT <br />CMP <br />Corrugated Metal Pipe <br />-- - <br />TEMPORARY EASEMENT <br />' <br />ENVIRONMENTALLY <br />R/W <br />Finished Grade <br />CO <br />SENSITIVE AREAS <br />FH <br />FOREIGN RIGHT-OF-WAY <br />CONC <br />Concrete <br />Acronym <br />Definition <br />Acronym Definition <br />(E) <br />Existing <br />DEG <br />Degree <br />(P) <br />Proposed <br />DET <br />Detail <br />AB <br />Aggregate Base <br />DFM <br />Distribution Feeder Main <br />ABN <br />Abandon <br />DI <br />Drainage Inlet <br />AC <br />Asphalt Concrete <br />DIA <br />Diameter <br />API <br />American Petroleum Institute <br />DIST <br />Distribution <br />APN <br />Assessor's Parcel Number <br />DPV <br />Damage Prevention Volume <br />APPROX <br />Approximate <br />DR <br />Distribution Regulator <br />AVE <br />Avenue <br />DREG <br />District Regulator <br />ARC <br />Abrasion Resistant Coating <br />DSAW <br />Double Submerged Arc -Welded <br />ASME <br />American Society of Mechanical <br />Engineers DWA <br />Deep Well Anode <br />ASTM <br />American Society for Testing Materials <br />DWY <br />Driveway <br />BBCL <br />Bell Bell Chill Ring <br />E <br />East <br />BC <br />Begin Curve <br />EASE <br />Easement <br />BD <br />Blowdown <br />EC <br />End Curve <br />BEG <br />Begin <br />ELECT <br />Electric <br />BKF <br />Backfill <br />ELEV <br />Elevation <br />BLDG <br />Building <br />EM <br />Electronic Marker <br />BLVD <br />Boulevard <br />EMS <br />Engineering Material Specification <br />BM <br />Bench Mark <br />ENGR <br />Engineer <br />BMP <br />Best Management Practice <br />EP <br />Edge of Pavement <br />BOM <br />Bill of Materials <br />EQ <br />Equation <br />BR <br />Bridge <br />ERW <br />Electric Resistance Welded <br />BTU <br />British Thermal Units <br />ESA <br />Environmentally Sensitive Area <br />BV <br />Ball Valve <br />ETS <br />Electrolysis Test Station <br />BW <br />Back of Walk <br />ETW <br />Edge of Traveled Way <br />CATS <br />Computer Automated Test Station F <br />Filter <br />CCV <br />Corrosion Control Volume <br />F & C <br />Frame and Cover <br />Cl <br />Cast Iron <br />FBE <br />Fusion Bonded Epoxy <br />CL <br />Centerline <br />FC <br />Face of Curb <br />CMP <br />Corrugated Metal Pipe <br />FDP <br />Future Design Pressure <br />CNG <br />Compressed Natural Gas <br />FG <br />Finished Grade <br />CO <br />County <br />FH <br />Fire Hydrant <br />CONC <br />Concrete <br />FIG <br />Figure <br />COND <br />Conduit <br />FL <br />Flow Line <br />CP <br />Cathodic Protection <br />FLG <br />Flange <br />CPT <br />Catch Point <br />FWY <br />Freeway <br />CROP <br />Conditional Reduction of Pressure <br />GS <br />Natural Gas Service <br />CTS <br />Coupon Test Station <br />GS&S <br />Gas Standards and Specifications <br />CU <br />Copper <br />GV <br />Gate Valve <br />CULV <br />Culvert <br />GW <br />Natural Gas Well <br />D <br />Depth <br />H <br />Horizontal <br />DE <br />Dead End <br />HDD <br />Horizontal Directional Drill <br />DCUST <br />Distribution Customer <br />HEW <br />High Frequency Weld <br />WARNING: <br />�``c <br />THIS DOCUMENT CONTAINS <br />CONFIDENTIAL, PROPRIETARY <br />INFORMATION THATIS THE SOLE' <br />PROPERTY OF PACIFIC GAS AND <br />ELECTRIC COMPANY <br />AND IS <br />INTENDED FOR USE ONLY BY <br />7 I i I 9 I _I.O <br />Acronym <br />Definition <br />HPR <br />High Pressure Regulator <br />DETAIL LEGEND: <br />r <br />GAS LINE MARKER (PADDLE DUAL) <br />C, <br />STORM DRAIN INLET <br />r=-- <br />PROPOSED GAS TRANSMISSION LINE <br />Invert <br />GAS LINE MARKER (PADDLE SINGLE) <br />Irrigation <br />UTILITY MANHOLE <br />Joint Pole <br />JT <br />Joint Trench <br />L <br />Line Number <br />LAT <br />Latitude <br />EXISTING GAS TRANSMISSION LINE <br />j <br />GAS LINE MARKER (POST) <br />Q <br />WATER METER <br />Location <br />TEMPORARY GAS TRANSMISSION LIIJE <br />Longitude <br />LT <br />Left <br />WATER VALVE <br />Monitor <br />(OWNED BY PG&E) <br />Maximum Allowable Operating Pressure <br />GAS LINE MARKER (OTHER) <br />Maximum <br />MH <br />Manhole <br />MIN <br />Minimum <br />MISC <br />Miscellaneous <br />CABLE TV BOX <br />- . <br />- . <br />TEMPORARY GAS TRANSMISSION LINE <br />Monument <br />INSULATION JOINT <br />Maximum Operating Pressure <br />MP <br />- _ <br />""' <br />(OWNED BY OTHERS) <br />® <br />PRESSURE CONTROL FITTING <br />Meter <br />TELECOMM BOX <br />_ <br />y <br />RETIRED GAS TRANSMISSION LINE <br />© <br />GAS BOX <br />T <br />TELECOMM VAULT <br />-_ <br />GAS TRANSMISSION LINE <br />Normal Operating Pressure <br />NPC <br />Non-Protected/Native Coupon <br />STREET LIGHT BOX <br />_: <br />---------- <br />(TO BE REMOVED) <br />HP <br />GAS HIGH PRESSURE REGULATOR <br />Original Ground <br />OH <br />Overhead <br />P <br />QM <br />GAS METER <br />Property Line <br />TREE <br />� � - - - <br />EXIST114G GAS DISTRIBUTION LINE <br />® <br />GAS DISTRICT REGULATOR <br />Parkway <br />ANODE <br />Plastic <br />ORIGINAL GROUND <br />© <br />PG&E GAS MANHOLE <br />D <br />DEEPWELL ANODE <br />II��I <br />CATS <br />COMPUTER <br />to <br />GAS VALVE <br />©GAS <br />VAULT <br />NUTOMATED <br />{{ <br />A <br />GAS VENT <br />CTS <br />COUPON TEST STATION <br />p <br />PIPE END CUT (SIDE) <br />W <br />GAS VALVE <br />ETS <br />ELECTROLYSIS TEST STATION <br />@ <br />PIPE END CUT <br />} <br />PG&E ELECTRIC MANHOLE <br />® <br />POLE -MOUNTED RECTIFIER <br />< FLOW <br />FLOW ARROW <br />ELECTRIC VAULT <br />POTHOLE <br />TIE-IN WELD <br />CITY/COUNTY MONUMENT <br />UTILITY POLE (ELECTRIC) <br />zs <br />MATERIAL OF RECORD ASSET <br />C <br />UTILITY POLE <br />MONUMENT, SEE DESCRIPTION <br />(OTHER) <br />ifi <br />BILL OF MATERIALS ASSET <br />SURVEY CONTROL POINT <br />j <br />JOINT POLE <br />CL <br />CENTERLINE <br />EXISTING ELECTRIC TOWER <br />Acronym <br />Definition <br />HPR <br />High Pressure Regulator <br />HWY <br />Highway <br />ID <br />Inside Diameter <br />ILI <br />In -Line Inspection <br />INV <br />Invert <br />IRR <br />Irrigation <br />1P <br />Joint Pole <br />JT <br />Joint Trench <br />L <br />Line Number <br />LAT <br />Latitude <br />LN <br />Lane <br />LNG <br />Liquid Natural Gas <br />LOC <br />Location <br />LONG <br />Longitude <br />LT <br />Left <br />M <br />Monitor <br />MAOP <br />Maximum Allowable Operating Pressure <br />MAX <br />Maximum <br />MH <br />Manhole <br />MIN <br />Minimum <br />MISC <br />Miscellaneous <br />MLV <br />Main Line Valve <br />MON <br />Monument <br />MOP <br />Maximum Operating Pressure <br />MP <br />Mile Point <br />MSP <br />Maximum Stopping Pressure <br />MTR <br />Meter <br />MW <br />Working Monitor <br />MWP <br />Maximum Working Pressure <br />N <br />North <br />NDE <br />Non -Destructive Examination <br />NOP <br />Normal Operating Pressure <br />NPC <br />Non-Protected/Native Coupon <br />NTS <br />Not to Scale <br />OD <br />Outside Pipe Diameter <br />OG <br />Original Ground <br />OH <br />Overhead <br />P <br />Pipeline <br />P/L <br />Property Line <br />PC <br />Point of Curvature <br />PCF <br />Pressure Control Fitting <br />PKWY <br />Parkway <br />PL <br />Plastic <br />PLC <br />Programmable Logic Controllers <br />AUTHOEfnot'aelflDt'S <br />RIZED PACIFIC GAS AND G3p6pE'l, 0 ISSUED FOR CONSTRUCTION <br />ELECTRIC COMPANY EMPLOYEES R No. DniE DESCRIPTION <br />AND ITS AGENTS. on h0fove VDU dig, <br />_ ©pG&Eco. REVISIONS <br />2 I of 3 I 4 5 0l I 6 <br />ME <br />Acronym <br />Definition <br />PSI <br />Pounds per Square Inch <br />PV <br />Plug Valve <br />PVMT <br />Pavement <br />QTY <br />Quantity <br />R <br />Radius <br />RCP <br />Reinforced Concrete Pipe <br />RD <br />Road <br />RDWY <br />Roadway <br />REG <br />Regulator <br />REL <br />Relocate <br />REPL <br />Replace <br />REV <br />Revision <br />RR <br />Railroad <br />RT <br />Right <br />RTE <br />Route <br />R/W <br />Right of Way <br />S <br />South <br />SAWN <br />Submerged Arc -Welded Helical <br />SAWL <br />Submerged Arc -Welded Longitudinal <br />SCADA <br />Supervisory Control and Data Acquisition <br />SO <br />Storm Drain <br />SG <br />Subgrade <br />SHT <br />Sheet <br />SMLS <br />Seamless <br />SMYS <br />Specified Minimum Yield Strength <br />SPEC <br />Specification <br />SS <br />Sanitary Sewer <br />SSAW <br />Single Submerged Arc -Welded <br />ST <br />Street <br />STA <br />Station <br />STD <br />Standard <br />STL <br />Steel <br />STPR <br />Strength Test Pressure Report <br />T <br />Tied (Connected to System) <br />TCE <br />Temporary Construction Easement <br />TCP <br />Traffic Control Plan <br />TO <br />Technical Document <br />TDW <br />T. D. Williamson <br />TEL <br />Telephone <br />TEMP <br />Temporary <br />TG <br />Top of Grade <br />TT <br />Top Tap <br />TSP <br />Transmission System Planning <br />TYP <br />Typical <br />CHNO RANIA I <br />APUD BY I (DATE 10/16/2017 <br />7 1 2 <br />Acronym <br />Definition <br />UG <br />Underground <br />USA <br />Underground Service Alert <br />UT <br />Ultra -Sonic Test <br />V <br />Valve <br />VIE <br />Verify in Field <br />VOL <br />Volume <br />W <br />Water <br />WT <br />Wall Thickness <br />WV <br />Water Valve <br />W/ <br />With <br />W/O <br />Without <br />WP <br />Work Procedure <br />PIPELINE - LEGEND & STAMPS <br />L-002 MP 144.26 & L-401 MP 321.73 <br />INSTALL 300' DEEP WELL ANODE <br />TRACY, CALIFORNIA <br />GAS TRANSMISSION & DISTRIBUTION <br />PACIFIC GAS AND ELECTRIC COMPANY <br />SAN FRANCISCO, CALIFORNIA <br />s n 9 3 <br />7AOiZ'111-SODS-LS.Jgn <br />=12 <br />BILLOFMATL SHEET6 <br />DWG LIST <br />TRACKING <br />NUMBER tC �l 092 <br />,,, I <br />SHEETNO. 3 OF 6 SHEETS <br />74012-94/ 0 <br />II <br />II ITRFnT <br />2 1 10 D INCH <br />I6-DCT-201706.00AM <br />E <br />FAR <br />1Dm <br />C <br />0 <br />AE <br />
The URL can be used to link to this page
Your browser does not support the video tag.