My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DARCY
>
901
>
2800 - Aboveground Petroleum Storage Program
>
PR0521964
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2019 11:27:20 AM
Creation date
8/24/2018 6:13:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0521964
PE
2832
FACILITY_ID
FA0012399
FACILITY_NAME
SWIFT TRANSPORTATION
STREET_NUMBER
901
STREET_NAME
DARCY
STREET_TYPE
PKWY
City
Lathrop
Zip
95330
APN
19822009
CURRENT_STATUS
01
SITE_LOCATION
901 DARCY PKWY
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\D\D ARCY\901\PR0521964\COMPLIANCE INFO 2003 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2011
QuestysRecordDate
11/7/2017 11:29:33 PM
QuestysRecordID
3719427
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06/11/2010 16:05 FAX 2098589280• SWIFT SHOP LATHROP 1? 005/007 <br /> SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Te/eplwne;(209)468-3420 Fax:(209)468-3433 Web:www.$)gov.oro/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility Facility <br /> Name: Swift Transportation Address: 901 D'arcy Parkway pate: 5/19/2010 <br /> VIOLATIONS <br /> N V y Code Section RSC=CA Health and Sana Code•CFR s Code of Federal ulatlorn•V•Vloletlon•RV=Re videlian <br /> 9 ro ulromenta of RSC 25270.4,5(a)ale IdenlMed n CFR code eeceona begInniry vath 112 <br /> 27 CFR 112.7(b) SPCC Plan felled to include a description of potential equipment failure(direction,flow rate, quantity),or <br /> provide equivalence as allowed by CFR 112.7(a <br /> 28 CFR 112.7(c) Felled dive <br /> to provide secondary containment and/or rsionary structures that are capable of containing <br /> discharge from primary containment until it is cleaned u <br /> Felled to provide explanation,conduct periodic integrity testing of containers and/or periodic integrity and <br /> 29 CFR 112.7(d) leak testing for valves and piping If containment or discharge prevention structures were determined to be <br /> Iftipfacticable on an SPCC Plan or sections of one that Is PE cortlfled <br /> If a response plan was not submitted to the RA, and containment or discharge prevention structures were <br /> 30 CFR 112.7(d) determined to be impracticable,the SPCC Pian failed to provide: (1)an oil spill contingency plan;(2) <br /> written commitment of manpower,equipment. materials to control and remove oil discharge <br /> 31 CFR 112.7(e) Failed to conduct Inspections and tests In accordance with written procedures and/or maintain signed <br /> records of Inspections and tests as required b the facility's SPCC Plan on site for 3 years <br /> h <br /> di <br /> l <br /> Failed to:(1)train personnel on discharge prevention; 2 nate a <br /> 32 CFR 112.7(1) ( )designate person to 6e accountable for <br /> di aIon; 3 schedule prevention discharge n•or revemion briefings at least annually <br /> A <br /> oil handling,processing and storage areas are secured and control <br /> led;to d=how the how <br /> 33 CFR 112.7(8) master flow and drain valves are secured; how unauthorized access to starter controls on oil pumps are <br /> prevented;how outobservice and Ioadlrg/unloeding connections are secured;the appropriateness of <br /> securl I htl •or vide equivalence as allowed CFR 112.7 a 2 <br /> Failed to provide sufficient secondary containment capacity for tank car or tank truck loading and <br /> 34 CFR 112.7(hX1) unloading area If drainage area is not designed to flow Into a catchment basin designed to handle <br /> discharges <br /> 35 CFR 112.7(h)(2) Failed to provide methods to prevent vehicles from departing loading and unloading areas before complete <br /> disconnection of transfer lines or provide equivalence as allowed by CFR 112.7 a 2 <br /> Failed to inspect lower-most drains and all outlets of vehlcles for discharge prior to filling and departure <br /> 36 CFR 112.7(hX3) and take appropriate measures to prevent liquid discharge while in transit or provide equivalence as <br /> allowed by CFR 112.7 a 2 <br /> Failed to evaluate field-constructed container for risk of discharge or failure due to brittle facture or other <br /> 37 CFR 1127(i) catastrophe after repair,alteratlon,reconstruction,or change In service,or provide equivalence as allowed <br /> by CFR 112.7a 2 <br /> SPCC Plan failed to Include a complete discussion of conformance to discharge prevention and <br /> 38 CFR 112.7(j) containment procedures as listed in part 112 and any applicable morestringent State rules, regulations, <br /> and ouidelines <br /> If a response plan was not submitted to the RA,and secondary containment is not provided for qualified <br /> 39 CFR 112.7(k)(2) oil-filled equipment,the SPCC Plan failed to:(I)establish and document procedures for inspection or a <br /> monitoring program to detect equipment failure and/or discharge;(ii)provide oil spill contingency plan <br /> and/or wrillan commitment of manpower,equipment, materials to control and remove oil discharge <br /> 40 CFR 112.8(b)(1) Failed to prevent discharge Into the drainage system from diked storage areas and/or Inspect <br /> accumulation prior to drainage,or provide equivalence as allowed by CFR 1 12.7 a 2 <br /> 41 CFR 112.8(bX2) Failed to use manual,open-and-closed design valves for the drainage of diked areas,or provide <br /> uivalence as allowed CFR 112.7(a)(2) <br /> Failed to design facility by <br /> system from undlked areas to flow into appropriate ponds, lagoons,or <br /> 42 CFR 112.8(b)(3) catchment basins(in areas not subject to flooding)designed to retain oil or return It to the facility,or <br /> provide equivalence as allowed by CFR 112.7 a Z <br /> Failed to equip the final discharge of all ditches with a diversion system that would retain oil in the facility in <br /> 43 CFR 112.8(b)(4) the evert of an uncontrolled discharge if CFR112.8(bX3)Is not met,or provide equivalence as allowed by <br /> CFR 112,7 a 2 <br /> 44 CFR 112.8(b)(5) Failed to provide Om TFF pumps,one permanently installed,where drainage waters are continuously <br /> treated In more than one treatment unit,or provide equivalence as allowed by CFR 112.7 a 2 <br /> 45 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions,or felled to provide equivalence as <br /> allowed by CFR 112.7 a 2 <br /> Failed to provide sufficient secondary containment capacity for a bulk storage tank that would hold the <br /> 46 CFR 112.8(cX2) volume of the largest container plus sufficient fraebo"to contain precipitation andfor diked area Is not <br /> sufficlAntly impervious to contain discharued oil <br /> Allowed drainage of uncontaminated rainwater from a diked area and failed to:(i)keep bypass valves <br /> 47 CFR 112.6(c)(3) sealed closed;(it)Inspect retained rainwater prior to discharge;(III)open bypass valve and reseal It under <br /> responsible supervision;(Iv)maintain adequate records of such events;or provide equivalence as allowed <br /> CFR 1112-7(a 2 <br /> IN 1_Fy mon.: R.wi�ed W. Tae: <br /> (208)953-7699 <br /> FHDII Rev Wwio Papa 2 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.