My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DARCY
>
901
>
2800 - Aboveground Petroleum Storage Program
>
PR0521964
>
COMPLIANCE INFO PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2019 11:27:20 AM
Creation date
8/24/2018 6:13:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0521964
PE
2832
FACILITY_ID
FA0012399
FACILITY_NAME
SWIFT TRANSPORTATION
STREET_NUMBER
901
STREET_NAME
DARCY
STREET_TYPE
PKWY
City
Lathrop
Zip
95330
APN
19822009
CURRENT_STATUS
01
SITE_LOCATION
901 DARCY PKWY
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\D\D ARCY\901\PR0521964\COMPLIANCE INFO 2003 - 2011.PDF
QuestysFileName
COMPLIANCE INFO 2003 - 2011
QuestysRecordDate
11/7/2017 11:29:33 PM
QuestysRecordID
3719427
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06/11/2010 16: 06 FAX 2088589280SWIFT SHOP LATHROP IA0061007 <br /> • <br /> SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax. (209)468-3433 Web:www.slgov.OrG/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility n,�Transportation Faakty Inspection <br /> Name: Address: 901 Darcy Parkway 5/19/2010 <br /> Date: <br /> VIOLATIONS <br /> e V v Code SeCdOn HSC-5k!! A11h and 394W Code:CFR=Code of Fedeml Readailons V-vialarlon:RV•Re t vlolan on <br /> 5 r4 OlrefneMe of HSC 2b2r0.4. a are IdaMdled ss CFR node aeCaonr inrli xifh 712 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 x CFR 112.8(cx6) Inspect containers and container supports;or keep records of inspections and tests,or provide <br /> ulvalence as allowed CFR 112,7(a)(2) <br /> 49 CFR 112.8(cx7) Failed to provlde effective leakage control through defective irdemal heating coils,or provide equivalence <br /> as allowed CFR 112.7 a 2 <br /> 50 CFR 112.8(c)(8) Failed to Install and reguledy fest approved liquid level sensing devices,or provide equivalence as allowed <br /> by CFR 112.7 a 2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> dlachame,or provide equivalence as allowed by CFR 112.7 a 2 <br /> 52 CFR 112.8(c)(10) Failed to pmmpUy correct visible discharges and/or remove accumulations of oil In diked areas,or provide <br /> e ulvalence as allowed CFR 11 2,7a 2 <br /> 53 CFR 112.8(cx11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> -capacity that will hold the volume of the largest container Djus sufficient:freeboard to contain reci itatlon <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(dx1) inspect buried piping for corrosion damage when exposed.or provide equivalence as allowed by CFR <br /> 1112.7(a)(2) <br /> 55 CFR 112.8(dx2) Failed to cep or blank-flarge terimnal connection at transfer point and mark its origin when piping is not in <br /> service or In standby service for an extended time or rookie ulvalence as allowed CFR 112.7 a 2 <br /> 56 CFR 112.8(dx3) Failed to design pipe supporta to minimize abreslon end corrosion and to allow for expansion and <br /> contrectlon or rovide ulvalence as allowed b CFR 112.7 a 2 <br /> 57 CFR 112.8(d)(4) Failed to reguledy inspect aboveground valves, plping, end appurtenances,or provide equivalence flo <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct Integrity and leak toot for buried piping at time of installation, modification,construction, <br /> relocation or replacement or rovide a uivalenca es allowed D CFR 112.7(a)(2) <br /> 59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering far <br /> to protect aboveground piping and other <br /> oil transfer operations or provide equivalence as allowed b CFR 11a2.7 2 <br /> 899 Other: See attached"Continuation-Oficial Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS 11,or MINOR-Notice to Comply) <br /> All violations are currently Minor, <br /> #2 Failed to conduct periodic inspections of the storage tank to assure compliance with CFR 112. <br /> #48 Failed to: test each aboveground container for integrity on a regular schedule or when repairs were <br /> made; inspect containers and container supports; or keep records of inspections and tests, or provide <br /> equivalence as allowed by CFR 112.7(a)(2). <br /> At time of inspection facility was not following listed testing and inspection schedule as described in <br /> SPCC. Begin implementing practices listed in SPCC plan. <br /> #10 Failed to complete a review and evaluation of SPCC plan at least once every five years. <br /> SPCC plan was prepared In July 2001 and has not been reviewed since. This plan is outdated and <br /> contains several errors. A complete review and evaluation of this plan Is necessary. Immediately review <br /> and update this plan according to CFR 112, <br /> Complete and submit the Return to Compliance certification to this office within 30 days (June 20, 2010), <br /> with a statement addressing how each of the above noted violations have been Corrected. The updated <br /> ALL EHD a TIME ASSOCIATED WITH FAILING To COMPLY BY THE ABOVE NOTED DATES WILL BE ELLLD AT THE CURRENT HOURLY RATE($115). <br /> THIS FACILITY 18 SL JECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> In 7 Rgns: <br /> Reeelved er: Tds: <br /> (209)953-7699 <br /> E Rev 2119110 Page 3 APSA INSPECTION REPORT <br />