Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEMCO RIPON TRUCK PLAZA INC 1022 E FRONTAGE RD RIPON March 18 2015 <br /> .5 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) " "- <br /> Item# Remarks <br /> 608 CFR 112.7(b) Plan failed to include a description of potential equipment failure or provide equivalence. <br /> Potential equipment failure and the resulting spill for existing ASTs was not addressed in the Spill Prevention, Control, <br /> and Countermeasure(SPCC) Plan. The SPCC Plan must include a prediction of the direction, rate of flow, and total <br /> quantity of oil which could be discharged from the facility as a result of major equipment failure. Immediately amend <br /> the SPCC Plan to include this information and submit a copy of the revision to the EHD, or provide equivalence as <br /> allowed by 40 CFR 112.7(a)(2). <br /> This is a minor violation. <br /> 609 CFR 112.7(c) Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge. <br /> A large crack was noted in the secondary containment wall that surrounds the four existing ASTs. No discussion of <br /> the adequacy of the secondary containment was provided in the SPCC plan. A facility shall provide appropriate <br /> containment and/or diversionary structures or equipment to prevent a discharge. The entire containment system, <br /> including walls and floor, must be capable of containing oil and must be constructed so that any discharge from a <br /> primary containment system will not escape the containment system before cleanup occurs. Immediately provide <br /> adequate secondary containment for all aboveground petroleum storage containers larger than 55 gallons. <br /> This is a Class II violation. <br /> 613 CFR 112.7(e) Failed to conduct inspections or maintain records for 3 years. <br /> No inspection or test records were available onsite. Inspections and tests must be conducted in accordance with the <br /> written procedures developed in the Spill Prevention, Control, and Countermeasure (SPCC) Plan. Records of these <br /> inspections and tests must be signed by the appropriate supervisor or inspector and kept on site with the SPCC Plan <br /> for a period of three years. Immediately locate a copy of all inspection and testing records for the last three years, <br /> maintain them on site, and submit copies to the EHD. <br /> This is a Class II violation. <br /> 614 CFR 112.7(f)(1) Failed to train personnel on discharge prevention. <br /> Oil handling personnel had no apparent training. At a minimum, oil handling personnel shall be trained in the operation <br /> and maintenance of equipment to prevent discharges; discharge procedure protocols; applicable pollution control laws, <br /> rules, and regulations; general facility operations; and the contents of the Spill Prevention, Control, and <br /> Countermeasure Plan. Immediately provide this training to all oil handling personnel and submit a copy of the training <br /> log to the EHD. <br /> This is a Class II violation. <br /> Received by , Inspector: Phone: Date: <br /> (initial): V IO_kA4ELENA MANZO, REHS (209) 953-7699 03/18/2015 <br /> lye m 1 age 6 of 8 <br />