Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Far:(209)468-3433 Web:www.sogov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEMCO RIPON TRUCK PLAZA INC 1 1022 E FRONTAGE RD RIPON March 18 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 602 CFR 112.7 Plan lacks approval of management to fully commit the necessary resources to implement the Plan. <br /> The Spill Prevention, Control, and Countermeasure(SPCC) Plan lacks approval of the current site management; <br /> ownership change took place in early 2014. The SPCC plan must have the full approval of management at a level of <br /> authority to commit the necessary resources to fully implement the Plan. Immediately obtain required management <br /> approval for the SPCC Plan for this facility. <br /> This is a Class II violation. <br /> 604 CFR 112.7(a)(3) No facility diagram or didn't show location and contents of containers, transfer stations, and pipes. <br /> No detailed facility diagram was available for review. The Spill Prevention, Control, and Countermeasure (SPCC) Plan <br /> shall include a facility diagram which must mark the location and contents of each fixed storage container and the <br /> storage area where mobile or portable containers are located. It must identify the location of and mark as"exempt' <br /> underground tanks. It must also include all transfer stations and connecting pipes, including intra-facility gathering <br /> lines. Immediately prepare the facility diagram to include all of the required information. Submit a legible copy of the <br /> updated facility diagram to the EHD for review. <br /> This is a Class II violation. <br /> 605 CFR 112.7(a)(3) Plan failed to address facility layout, operations discharge prevention methods and containers. <br /> The storage capacity of the existing ASTs is inaccurate, the plan lists AST storage capacities as 15,000 gallons and <br /> not the existing 20,000 gallons. The following shall be addressed in the Spill Prevention, Control, and Countermeasure <br /> (SPCC) Plan: <br /> -type of oil in each fixed container and it's storage capacity. For mobile or potable containers, the type of oil and <br /> storage capacity for each container or an estimate of the potential number of mobile or portable containers, the types <br /> of oil, and anticipated storage capacities <br /> -discharge prevention measures including procedures for routine handling of products <br /> -discharge or drainage controls such as secondary containment, equipment, and procedures for the control of a <br /> discharge <br /> -countermeasures for discharge discovery, response, and cleanup <br /> - methods of disposal of recovered materials <br /> -contact list and phone numbers for the facility response coordinator, National Response Center, cleanup <br /> contractors, and all appropriate Federal, State, and local agencies. <br /> Immediately amend the SPCC Plan to include all required information. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): V I C& pQ kA ELENA MANZO, REHS (209) 953-7699 03/18/2015 <br /> MN' e5ofS <br />