My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sioov.orq/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEMCO RIPON TRUCK PLAZA INC 1022 E FRONTAGE RD, RIPON October 10, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 712 CFR 112.8(c)(6) Failed to test or inspect each container for integrity based on industry standards. <br /> No integrity testing has been conducted for the four diesel tanks,and the 55 gallon drum of waste diesel. <br /> Inspections and testing shall be conducted on all aboveground liquid petroleum containers larger than 55 gallons, <br /> and all 55 gallon drums of oil. Records of these inspections and tests shall be signed by the appropriate supervisor <br /> or inspector and kept on site with the Spill Prevention, Control,and Countermeasure(SPCC)Plan for a period of <br /> three years. Immediately begin necessary testing and inspections for all Aboveground Petroleum Storage Act <br /> regulated containers and maintain on site with the SPCC Plan. <br /> This is a repeat violation,Class II. <br /> 714 CFR 112.8(c)(8)(i-iv)Failed to provide each container with a high level monitoring device. <br /> 1)There was no high liquid monitoring device on the 55 gallon drum of waste diesel. <br /> 2)Diesel tank 3 was observed with a high liquid level sensing device with a small vision gauge facing away from the <br /> fill pipe.This vision gauge could not be seen or monitored from the fill pipe. <br /> At least one of the following devices must be installed in each container: <br /> -High liquid level alarm with audible or visual signal <br /> -High liquid level pump cutoff device set to stop flow at a predetermined content level <br /> -Direct audible or code signal communication between the container gauger and the pumping station <br /> -Fast response system,such as digital computer,telepulse, or direct vision gauge. If a direct vision gauge is <br /> being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br /> filling of the tanks. <br /> Immediately install an approved liquid level sensing device in accordance with CFR 112.8 and implement necessary <br /> procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class It violation. <br /> 715 CFR 112.8(c)(8)(v)Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> Liquid level sensing devices have not been tested for diesel tank 3. Procedures and frequency of testing for these <br /> devices were not addressed in the Spill Prevention, Control, and Countermeasure(SPCC)plan. Liquid level <br /> sensing devices must be installed in accordance with CFR 112.8 and shall be regularly tested to ensure proper <br /> operation. Immediately conduct all necessary testing of liquid level sensing devices, or provide equivalence as <br /> allowed by CFR 112.7(a)(2). <br /> This is a repeat violation,Class Il. <br /> 717 CFR 112.8(c)(10)Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br /> An active leak of oily liquid was observed at the diesel fill pipe,and at the diesel fill motor.There was visible staining <br /> around the diesel fill pipe, and the diesel fill motor.Also,there was a bucket filled with oily liquid at the motor closest <br /> to tank 4.According to Dayal Dess(worker),the bucket was placed there because the piping sometimes leaks. <br /> Visible discharges which result in a loss of oil from a container, including but not limited to seams,gaskets, piping, <br /> pumps,valves, rivets,and bolts, must be promptly Corrected. Immediately fix the leak,clean the pooled discharge, <br /> and manage according to the California Code of Regulations Title 22 hazardous waste regulations. <br /> This is a repeat violation, Class II. <br /> FA0000650 PRO516198 SCO01 10/1012017 <br /> EHD 28-01 Rev.09122116 Page 9 of 11 Aboveground Petroleum Storage Act OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.