My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
3112
>
2800 - Aboveground Petroleum Storage Program
>
PR0535482
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2019 3:46:58 PM
Creation date
8/24/2018 6:42:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0535482
PE
2832
FACILITY_ID
FA0003790
FACILITY_NAME
LDS - STOCKTON BISHOPS STOREHOUSE
STREET_NUMBER
3112
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17910008
CURRENT_STATUS
01
SITE_LOCATION
3112 LOOMIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\L\LOOMIS\3112\PR0535482\COMPLIANCE INFO.pdf
QuestysFileName
COMPLIANCE INFO
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />LDS - STOCKTON BISHOPS STOREHOUSE <br />Facility Address: <br />3112 LOOMIS RD, STOCKTON, CA 95205 <br />Facility Phone: <br />(951) 361-0924 <br />Program: <br />2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE <br />Inspection Type: <br />ROUTINE INSPECTION -Operating Permit <br />Date: <br />February 02, 2016 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209) 468-3420 Fax :(209) 468-3433 Web:www .sjgov .org /ehd <br />CERS ID: <br />10181423 <br />Inspection Contact: <br />Bill Allmendinger <br /> Consent For : Consent Given By: <br />Linda Allmendinger, Storehouse Manager <br />Title: <br />Storehouse Manager <br />Phone: <br />(209 )943-1892 <br />Inspection Photos Samples <br />R = Repeat violation COS = Corrected on site during inspection V = Violation <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />Aboveground Petroleum Storage Act <br />101 ■ V □ R ■ COS Failed to prepare and implement a written SPCC Plan in accordance with CFR Part 112 HSC 25270.4.5(a) <br />102 □ V □ R □ COS Failed to properly close a tank that is considered permanently closed HSC 25270.4.5(a) <br />103 □ V □ R □ COS Failed to file Business Plan or annual facility tank statement if capacity is over 10,000 gallons HSC 25270.6(a) <br />104 □ V □ R □ COS Failed to submit APSA fees HSC 25270.6(b) <br />105 □ V □ R □ COS Failed to report spills or releases of 42 gallons (one barrel) or more HSC 25270.8 <br />106 □ V □ R □ COS Failed to submit a written response within 30 days of receiving an inspection report CCR 25185(c)(3) <br />107 □ V □ R □ COS Failed to report program data electronically HSC 25404(e)(4) <br />Requirement to Prepare and Implement a SPCC Plan <br />201 ■ V □ R □ COS Plan certification by a Professional Engineer (PE) missing or incomplete CFR 112.3(d) <br />202 □ V □ R □ COS Failed to maintain a copy of the Plan on site CFR 112.3(e)(1) <br />Amendment of SPCC Plan by Owners or Operators <br />301 □ V □ R □ COS Failed to amend Plan as necessary CFR 112.5(a) <br />302 □ V □ R □ COS Failed to review Plan once every five years and/or implement any resulting amendments CFR 112.5(b) <br />303 □ V □ R □ COS Failed to have a PE certify technical amendments CFR 112.5(c) <br />General Requirements for SPCC Plans <br />601 ■ V □ R □ COS Plan that does not follow the sequence specified in this section lacks a cross-referencing section CFR 112.7 <br />602 □ V □ R □ COS Plan lacks approval of management to fully commit the necessary resources to implement the Plan CFR 112.7 <br />603 □ V □ R □ COS Plan failed to discuss equivalent environmental protection, if applicable CFR 112.7(a)(2) <br />604 □ V □ R □ COS No facility diagram or didn't show location and contents of containers, transfer stations, and pipes CFR 112.7(a)(3) <br />605 ■ V □ R □ COS Plan failed to address facility layout, operations discharge prevention methods and containers CFR 112.7(a)(3) <br />606 □ V □ R □ COS Plan failed to contain procedures for reporting a discharge CFR 112.7(a)(4) <br />607 □ V □ R □ COS Discharge procedures are not adequately addressed if the facility has no response plan CFR 112.7(a)(5) <br />608 □ V □ R □ COS Plan failed to include a description of potential equipment failure or provide equivalence CFR 112.7(b) <br />609 □ V □ R □ COS Failed to provide secondary containment, diversionary structures, or equipment to prevent discharge CFR 112.7(c) <br />610 □ V □ R □ COS Full or partial PE certified Plan failed to explain impracticability CFR 112.7(d) <br />611 □ V □ R □ COS Full or partial PE certified Plan failed to include spill contingency if no response plan submitted CFR 112.7(d)(1) <br />612 □ V □ R □ COS No written commitment of manpower, equipment, and materials to control and remove oil discharge CFR 112.7(d)(2) <br />613 ■ V □ R □ COS Failed to conduct inspections or maintain records for 3 years CFR 112.7(e) <br />Page 1 of 6
The URL can be used to link to this page
Your browser does not support the video tag.