Laserfiche WebLink
Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />February 02, 2016 <br />Facility Address: <br />3112 LOOMIS RD, STOCKTON <br />Facility Name: <br />LDS - STOCKTON BISHOPS STOREHOUSE <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone:(209) 468-3420 Fax :(209) 468-3433 Web:www .sjgov .org /ehd <br />General Requirements for SPCC Plans <br />614 □ V □ R □ COS Failed to train personnel on discharge prevention CFR 112.7(f)(1) <br />615 □ V □ R □ COS Failed to designate a person accountable for discharge prevention CFR 112.7(f)(2) <br />616 ■ V □ R □ COS Failed to schedule and conduct discharge prevention briefings at least annually CFR 112.7(f)(3) <br />617 □ V □ R □ COS Plan failed to address security of site and valves, lock out/tag out, and lighting CFR 112.7(g) <br />618 □ V □ R □ COS Loading/unloading rack containment system not properly sized CFR 112.7(h)(1) <br />619 □ V □ R □ COS Failed to provide vehicular departure system loading and unloading racks CFR 112.7(h)(2) <br />620 □ V □ R □ COS Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles CFR 112.7(h)(3) <br />621 □ V □ R □ COS Failed to evaluate field constructed container for brittle fracture and take appropriate action CFR 112.7(i) <br />622 □ V □ R □ COS Failed to include discussion of conformance to discharge prevention and containment procedures CFR 112.7(j) <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br />701 □ V □ R □ COS Failed to use manual open-and-closed design valves for the drainage of diked areas CFR 112.8(b)(2) <br />702 □ V □ R □ COS Failed to design facility drainage system from undiked areas to retain in the facility CFR 112.8(b)(3), <br />112.8(b)(4) <br />703 □ V □ R □ COS Failed to provide two lift pumps for more than one continuous treatment unit CFR 112.8(b)(5) <br />704 □ V □ R □ COS Diked area is not sufficiently impervious to contain discharged oil CFR 112.8(c)(2) <br />705 □ V □ R □ COS Container not compatible with oil stored and/or storage conditions CFR 112.8(c)(1) <br />706 □ V □ R □ COS Failed to provide and maintain adequate secondary containment CFR 112.8(c)(2) <br />707 □ V □ R □ COS Failed to keep containment bypass valves closed when not draining rainwater CFR 112.8(c)(3)(i) <br />708 □ V □ R □ COS Failed to inspect retained rainwater prior to discharge CFR 112.8(c)(3)(ii) <br />709 □ V □ R □ COS Failed to open and close bypass valve to drain rainwater under responsible supervision CFR 112.8(c)(3)(iii) <br />710 □ V □ R □ COS Failed to maintain records of drainage from diked areas CFR 112.8(c)(3)(iv) <br />711 □ V □ R □ COS Failed to provide corrosion protection for partially buried tanks CFR 112.8(c)(5) <br />712 □ V □ R □ COS Failed to perform tank inspections that take into account size, configuration, and design CFR 112.8(c)(6) <br />713 ■ V □ R □ COS Failed to perform scheduled tank tests and inspections by appropriately qualified personnel CFR 112.8(c)(6) <br />714 □ V □ R □ COS Failed to test and inspect containers by appropriately qualified personnel after material repairs CFR 112.8(c)(6) <br />715 □ V □ R □ COS Failed to provide effective leakage control through defective internal heating coils CFR 112.8(c)(7) <br />716 □ V □ R □ COS Failed to provide each container with a high level monitoring device CFR 112.8(c)(8)(i-iv) <br />717 □ V □ R □ COS Failed to regularly test liquid level sensing devices to ensure proper operation CFR 112.8(c)(8)(v) <br />718 □ V □ R □ COS Failed to observe effluent treatment frequently enough to detect potential discharge CFR 112.8(c)(9) <br />719 □ V □ R □ COS Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas CFR 112.8(c)(10) <br />720 □ V □ R □ COS Failed to provide sufficient secondary containment capacity for mobile or portable containers CFR 112.8(c)(11) <br />721 □ V □ R □ COS Failed to locate mobile or portable containers to prevent discharge CFR 112.8(c)(11) <br />722 □ V □ R □ COS Failed to take corrective action on buried piping when exposed for any reason CFR 112.8(d)(1) <br />723 □ V □ R □ COS Failed to provide corrosion protection for buried piping CFR 112.8(d)(1) <br />724 □ V □ R □ COS Failed to cap/blank-flange connection at transfer point and mark its origin if not in service CFR 112.8(d)(2) <br />Page 2 of 6