My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
19501
>
2800 - Aboveground Petroleum Storage Program
>
PR0528459
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:27 PM
Creation date
8/24/2018 6:53:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528459
PE
2832
FACILITY_ID
FA0010217
FACILITY_NAME
CALIFORNIA FREIGHT
STREET_NUMBER
19501
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
CURRENT_STATUS
01
SITE_LOCATION
19501 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\HWY 99\19501\PR0528459\COMPLIANCE INFO 2018 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2018 - PRESENT
QuestysRecordDate
8/15/2018 6:45:14 PM
QuestysRecordID
3963189
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.s'gov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility M Facility A) ] &TC4 Inspecti <br /> Name: Address:" ale <br /> 0 0 <br /> VIOLATIONS <br /> # VCode Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations;V=Violation;RV=Repeat violation <br /> Specific requirements of HSC 25270.4.5(a)are identified as CFR code sections beginning with 112 <br /> Failed to: test each aboveground container for integrity on a regular schedule or when repairs were made; <br /> 48 CFR 112.8(c)(6) inspect containers and container supports; or keep records of inspections and tests,or provide <br /> equivalence as allowed by CFR 112.7(a)(2 <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils, or provide equivalence <br /> as allowed by CFR 112.7(a)(2) <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices, or provide equivalence as allowed <br /> by CFR 112.7(a)(2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 52 / CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas, or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 53 CFR 112.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed, or provide equivalence as allowed by CFR <br /> 112.7(a)(2) <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 57 / CFR 112.8(d)(4) Failed to regularly inspect aboveground valves, piping, and appurtenances, or provide equivalence as <br /> / allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation, modification, construction, <br /> relocation, or replacement, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 59 ::LFR Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br /> oil transfer operations, or provide equivalence as allowed b CFR 112.7(a)(2) <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Phone. Re ei ed By. Title: <br /> EHD 28-02 Rev 2/19/10 Pag AP INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.